dc.description.abstractA sensitive, selective and reliable electrochemical method for the determination of nicotine using differential pulse voltammetry on a bare boron-doped diamond electrode has been developed. Nicotine yielded a single oxidation peak at a highly positive potential of +1.45 V (vs. Ag/AgCl/3 M KCl) in Britton-Robinson buffer solution at pH 8. The influence of supporting electrolyte, pH and scan rate on the current response of NIC was investigated. At optimized experimental conditions, a linear relation between peak current and concentration of nicotine was found for the range from 0.5 to 200 mu M (0.08-32.9 mg L-1) with a detection limit of 0.3 mu M (0.05 mg L-1) and a good repeatability (relative standard deviation of 2.1% at 25 mu M concentration level, n = 10) was achieved without any electrode surface modification. The practical usefulness of the developed procedure was successfully demonstrated with the determination of nicotine in tobacco products and anti-smoking pharmaceuticals with results similar to those obtained by a high-performance liquid chromatography and to the contents declared by the manufacturer, respectively. Prior to analysis, the sample pretreatment includes only sonication and/or simple liquid-liquid extraction. The proposed sensor represents an effective electrochemical tool and a promising alternative for quality control analysis of products in tobacco and pharmaceutical industry. (C) 2013 Elsevier B.V. All rights reserved.en
dc.publisherElsevier Science Sa, Lausanne
dc.relationinfo:eu-repo/grantAgreement/MESTD/Basic Research (BR or ON)/172030/RS//
dc.relationBilateral program Action: Austria-Slovakia
dc.relationGrant Agency of the Slovak Republic [1/0051/13]
dc.relationSlovak Research and Development Agency [APVV-0797-11]
dc.rightsrestrictedAccess
dc.sourceDiamond and Related Materials
dc.subjectNicotineen
dc.subjectOxidationen
dc.subjectBoron-doped diamond electrodeen
dc.subjectVoltammetryen
dc.subjectTobacco producten
dc.subjectAnti-smoking pharmaceuticalen
dc.titleBoron-doped diamond electrochemical sensor for sensitive determination of nicotine in tobacco products and anti-smoking pharmaceuticalsen
dc.typearticle
dc.rights.licenseARR
dcterms.abstractСворц, Лубомир; Калцхер, Курт; Станковић, Далибор;
dc.citation.volume42
dc.citation.spage1
dc.citation.epage7
dc.identifier.wos000332910400002
dc.identifier.doi10.1016/j.diamond.2013.11.012
dc.citation.other42: 1-7
dc.citation.rankM22
dc.type.versionpublishedVersionen
dc.identifier.scopus2-s2.0-84896539707