Show simple item record

dc.creatorTu, Ran
dc.creatorMartinez, Ronny
dc.creatorProdanović, Radivoje
dc.creatorKlein, Mathias
dc.creatorSchwaneberg, Ulrich
dc.date.accessioned2018-11-22T00:18:10Z
dc.date.available2018-11-22T00:18:10Z
dc.date.issued2011
dc.identifier.issn1087-0571
dc.identifier.urihttps://cherry.chem.bg.ac.rs/handle/123456789/1158
dc.description.abstractProteases are industrially important enzymes but often have to be improved for their catalytic efficiency and stabilities to suit applications. Flow cytometry screening technology based on in vitro compartmentalization in double emulsion had been developed and applied on directed evolution of paraoxonase and beta-galactosidase. Further advancements of flow cytometry-based screening technologies will enable an ultra-high throughput of variants offering novel opportunities in directed enzyme evolution under high mutational loads. For the industrially important enzyme class of proteases, a first flow cytometry-based screening system for directed protease evolution has been developed based on an extracellular protease-deficient Bacillus subtilis strain (WB800N), a model protease (subtilisin Carlsberg), and a water-in-oil-in-water double-emulsion technology. B. subtilis WB800N cells are encapsulated in double emulsion with a fluorogenic substrate (rhodamine 110-containing peptide), allowing the screening of protease variants in femtoliter compartments at high throughput. The protease screening technology was validated by employing an epPCR mutant library with a high mutational load and screened for increased resistance toward the inhibitor antipain dihydrochloride. A variant (K127R, T237P, M239I, I269V, Y310F, I372V) with an improved relative resistance was isolated from a small population of active variants, validating the reported protease flow cytometry screening technology for increased inhibitor resistance. (Journal of Biomolecular Screening 2011;16:285-294)en
dc.publisherSage Publications Inc, Thousand Oaks
dc.relationBMBF [FKZ 0313137]
dc.rightsrestrictedAccess
dc.sourceJournal of Biomolecular Screening
dc.subjectdirected evolutionen
dc.subjectproteaseen
dc.subjectflow cytometryen
dc.subjectin vitro compartmentalizationen
dc.subjecthigh throughputen
dc.titleA Flow Cytometry-Based Screening System for Directed Evolution of Proteasesen
dc.typearticle
dc.rights.licenseARR
dcterms.abstractМартинез, Роннy; Ту, Ран; Клеин, Матхиас; Продановић, Радивоје; Сцхwанеберг, Улрицх;
dc.citation.volume16
dc.citation.issue3
dc.citation.spage285
dc.citation.epage294
dc.identifier.wos000288037900001
dc.identifier.doi10.1177/1087057110396361
dc.citation.other16(3): 285-294
dc.citation.rankM22
dc.identifier.pmid21335599
dc.description.otherFree full text: [https://doi.org/10.1177/1087057110396361]
dc.type.versionpublishedVersion
dc.identifier.scopus2-s2.0-79954615462


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record