Prikaz svih podataka o dokumentuApstrakt
In this paper electrochemical behavior and sensitive determination of vitamin B12 was studied by using boron doped diamond (BDD) electrode. Cyclic voltammetry and square wave voltammetry were used to investigate the performance of BDD electrode for this purpose. The calibration curve, constructed by plotting oxidation peak current against concentration, obtained in Britton-Robinson buffer solution at pH 2.0 was linear over the wide concentration range of 2-35 mu M with detection limit of 0.7 mu M. Influence of most common interferences compounds was investigated and proposed procedure was successfully applied for quantification of vitamin B12 in real samples, with satisfactory recovery (98-105%). (C) 2016 The Electrochemical Society. All rights reserved.
Izvor:
Journal of the Electrochemical Society, 2016, 163, 7Izdavač:
- Electrochemical Soc Inc, Pennington
Finansiranje / projekti:
- Primena unapređenih oksidacionih procesa i nanostrukturisanih oksidnih materijala za uklanjanje zagađivača iz životne sredine, razvoj i optimizacija instrumentalnih tehnika za praćenje efikasnosti (RS-MESTD-Basic Research (BR or ON)-172030)
DOI: 10.1149/2.1041607jes
ISSN: 0013-4651
WoS: 000377412900058
Scopus: 2-s2.0-85062115412
Institucija/grupa
Hemijski fakultet / Faculty of ChemistryTY - JOUR AU - Stanković, Dalibor AU - Kuzmanović, Darko AU - Manojlović, Dragan D. AU - Kalcher, Kurt AU - Roglić, Goran PY - 2016 UR - https://cherry.chem.bg.ac.rs/handle/123456789/2258 AB - In this paper electrochemical behavior and sensitive determination of vitamin B12 was studied by using boron doped diamond (BDD) electrode. Cyclic voltammetry and square wave voltammetry were used to investigate the performance of BDD electrode for this purpose. The calibration curve, constructed by plotting oxidation peak current against concentration, obtained in Britton-Robinson buffer solution at pH 2.0 was linear over the wide concentration range of 2-35 mu M with detection limit of 0.7 mu M. Influence of most common interferences compounds was investigated and proposed procedure was successfully applied for quantification of vitamin B12 in real samples, with satisfactory recovery (98-105%). (C) 2016 The Electrochemical Society. All rights reserved. PB - Electrochemical Soc Inc, Pennington T2 - Journal of the Electrochemical Society T1 - Electroanalytical Approach for Vitamin B-12 Quantification Based on Its Oxidation at Boron Doped Diamond Electrode VL - 163 IS - 7 DO - 10.1149/2.1041607jes ER -
@article{ author = "Stanković, Dalibor and Kuzmanović, Darko and Manojlović, Dragan D. and Kalcher, Kurt and Roglić, Goran", year = "2016", abstract = "In this paper electrochemical behavior and sensitive determination of vitamin B12 was studied by using boron doped diamond (BDD) electrode. Cyclic voltammetry and square wave voltammetry were used to investigate the performance of BDD electrode for this purpose. The calibration curve, constructed by plotting oxidation peak current against concentration, obtained in Britton-Robinson buffer solution at pH 2.0 was linear over the wide concentration range of 2-35 mu M with detection limit of 0.7 mu M. Influence of most common interferences compounds was investigated and proposed procedure was successfully applied for quantification of vitamin B12 in real samples, with satisfactory recovery (98-105%). (C) 2016 The Electrochemical Society. All rights reserved.", publisher = "Electrochemical Soc Inc, Pennington", journal = "Journal of the Electrochemical Society", title = "Electroanalytical Approach for Vitamin B-12 Quantification Based on Its Oxidation at Boron Doped Diamond Electrode", volume = "163", number = "7", doi = "10.1149/2.1041607jes" }
Stanković, D., Kuzmanović, D., Manojlović, D. D., Kalcher, K.,& Roglić, G.. (2016). Electroanalytical Approach for Vitamin B-12 Quantification Based on Its Oxidation at Boron Doped Diamond Electrode. in Journal of the Electrochemical Society Electrochemical Soc Inc, Pennington., 163(7). https://doi.org/10.1149/2.1041607jes
Stanković D, Kuzmanović D, Manojlović DD, Kalcher K, Roglić G. Electroanalytical Approach for Vitamin B-12 Quantification Based on Its Oxidation at Boron Doped Diamond Electrode. in Journal of the Electrochemical Society. 2016;163(7). doi:10.1149/2.1041607jes .
Stanković, Dalibor, Kuzmanović, Darko, Manojlović, Dragan D., Kalcher, Kurt, Roglić, Goran, "Electroanalytical Approach for Vitamin B-12 Quantification Based on Its Oxidation at Boron Doped Diamond Electrode" in Journal of the Electrochemical Society, 163, no. 7 (2016), https://doi.org/10.1149/2.1041607jes . .