Kinetic spectrophotometric method for gold(III) determination
Samo za registrovane korisnike
2005
Članak u časopisu (Objavljena verzija)
Metapodaci
Prikaz svih podataka o dokumentuApstrakt
The kinetic spectrophotometric method for Au(III) determination was developed and validated. It was based on the catalytic effect of gold on the oxidation of methylene blue B (3,7di-(dimethyl amino)-10-dehydro-phenotiazin chloride) by ammonium peroxo-disulfate in citric buffer solution. There was the linearity of the calibration curve in the concentration range from 0.09 to 2.90 mu g ml(-1) Au(III). The relative standard deviation was 2.50% and correlation coefficient of 0.9999. The limit of detection was determined as signal to noise ratio (3: 1) and it was 5.5 ng ml(-1). The limit of quantification, based on signal to noise ratio 10: 1 was 19.25 ng ml(-1). The selectivity was tested on the basis of influence of known amounts of different ions in the reaction mixture, upon the reaction rate. Kinetic and thermodynamic parameters were reported for both catalytic and non-catalytic reactions. The method was verified by Au(III) determination in anti-rheumatic drug "Thuredon" and in human u...rine samples, using ICP-AES as the comparative method. As the method is accurate, reliable, quick and simple it could be useful for clinical and toxicological practice. (c) 2004 Elsevier B.V. All rights reserved.
Ključne reči:
gold(III) / spectrophotometric kinetic method / anti-rheumatic drug / urineIzvor:
Analytica Chimica Acta, 2005, 547, 1, 144-149Izdavač:
- Elsevier Science Bv, Amsterdam
DOI: 10.1016/j.aca.2004.11.078
ISSN: 0003-2670
WoS: 000231177500024
Scopus: 2-s2.0-23044452050
Kolekcije
Institucija/grupa
Hemijski fakultet / Faculty of ChemistryTY - JOUR AU - Rancic, SM AU - Nikolić-Mandić, Snežana D. AU - Mandić, Ljuba M. PY - 2005 UR - https://cherry.chem.bg.ac.rs/handle/123456789/726 AB - The kinetic spectrophotometric method for Au(III) determination was developed and validated. It was based on the catalytic effect of gold on the oxidation of methylene blue B (3,7di-(dimethyl amino)-10-dehydro-phenotiazin chloride) by ammonium peroxo-disulfate in citric buffer solution. There was the linearity of the calibration curve in the concentration range from 0.09 to 2.90 mu g ml(-1) Au(III). The relative standard deviation was 2.50% and correlation coefficient of 0.9999. The limit of detection was determined as signal to noise ratio (3: 1) and it was 5.5 ng ml(-1). The limit of quantification, based on signal to noise ratio 10: 1 was 19.25 ng ml(-1). The selectivity was tested on the basis of influence of known amounts of different ions in the reaction mixture, upon the reaction rate. Kinetic and thermodynamic parameters were reported for both catalytic and non-catalytic reactions. The method was verified by Au(III) determination in anti-rheumatic drug "Thuredon" and in human urine samples, using ICP-AES as the comparative method. As the method is accurate, reliable, quick and simple it could be useful for clinical and toxicological practice. (c) 2004 Elsevier B.V. All rights reserved. PB - Elsevier Science Bv, Amsterdam T2 - Analytica Chimica Acta T1 - Kinetic spectrophotometric method for gold(III) determination VL - 547 IS - 1 SP - 144 EP - 149 DO - 10.1016/j.aca.2004.11.078 ER -
@article{ author = "Rancic, SM and Nikolić-Mandić, Snežana D. and Mandić, Ljuba M.", year = "2005", abstract = "The kinetic spectrophotometric method for Au(III) determination was developed and validated. It was based on the catalytic effect of gold on the oxidation of methylene blue B (3,7di-(dimethyl amino)-10-dehydro-phenotiazin chloride) by ammonium peroxo-disulfate in citric buffer solution. There was the linearity of the calibration curve in the concentration range from 0.09 to 2.90 mu g ml(-1) Au(III). The relative standard deviation was 2.50% and correlation coefficient of 0.9999. The limit of detection was determined as signal to noise ratio (3: 1) and it was 5.5 ng ml(-1). The limit of quantification, based on signal to noise ratio 10: 1 was 19.25 ng ml(-1). The selectivity was tested on the basis of influence of known amounts of different ions in the reaction mixture, upon the reaction rate. Kinetic and thermodynamic parameters were reported for both catalytic and non-catalytic reactions. The method was verified by Au(III) determination in anti-rheumatic drug "Thuredon" and in human urine samples, using ICP-AES as the comparative method. As the method is accurate, reliable, quick and simple it could be useful for clinical and toxicological practice. (c) 2004 Elsevier B.V. All rights reserved.", publisher = "Elsevier Science Bv, Amsterdam", journal = "Analytica Chimica Acta", title = "Kinetic spectrophotometric method for gold(III) determination", volume = "547", number = "1", pages = "144-149", doi = "10.1016/j.aca.2004.11.078" }
Rancic, S., Nikolić-Mandić, S. D.,& Mandić, L. M.. (2005). Kinetic spectrophotometric method for gold(III) determination. in Analytica Chimica Acta Elsevier Science Bv, Amsterdam., 547(1), 144-149. https://doi.org/10.1016/j.aca.2004.11.078
Rancic S, Nikolić-Mandić SD, Mandić LM. Kinetic spectrophotometric method for gold(III) determination. in Analytica Chimica Acta. 2005;547(1):144-149. doi:10.1016/j.aca.2004.11.078 .
Rancic, SM, Nikolić-Mandić, Snežana D., Mandić, Ljuba M., "Kinetic spectrophotometric method for gold(III) determination" in Analytica Chimica Acta, 547, no. 1 (2005):144-149, https://doi.org/10.1016/j.aca.2004.11.078 . .