@article{
author = "Vlajkovic, Jelena and Andrić, Filip and Ristivojević, Petar and Radoičić, Aleksandra and Tešić, Živoslav Lj. and Milojković-Opsenica, Dušanka",
year = "2013",
abstract = "A novel reversed-phase thin-layer chromatographic (RP-TLC) method was developed for simultaneous determination of ten most commonly used artificial food dyes. The method was validated with respect to specificity, linearity, precision, and accuracy and compared with reversed-phase high performance liquid chromatography (RP-HPLC) method. In the case of TLC method horizontal developing technique was employed using octadecyl-modified silica as a stationary phase and 0.5mol dm(-3) ammonium sulfate in 30% of ethanol-water solution as a mobile phase. HPLC analysis was carried out using XDB-C18 column and gradient of mixture of aqueous ammonium acetate solution (0.1moldm(-3), pH=6.5) and MeOH/ACN (1:1, v/v). Colorants were detected at 450, 500, and 625nm wavelengths. The TLC method proved to be suitable for quantitative determination in relatively wide range of concentrations (20-300ng/band). Satisfactory values of limits of detection and quantitation were established for both techniques, although somewhat higher in the case of TLC, ranging from 2-10ng/band, that is, 3-20ng/band. Both methods can be applied with satisfactory precision and accuracy, with clear advantage of TLC for simultaneous analysis of six samples per hour.",
publisher = "Taylor & Francis Inc, Philadelphia",
journal = "Journal of Liquid Chromatography and Related Technologies",
title = "Development and Validation of a Tlc Method for the Analysis of Synthetic Food-Stuff Dyes",
volume = "36",
number = "17",
pages = "2476-2488",
doi = "10.1080/10826076.2013.790771"
}