Tešanović, Slavna

Link to this page

Authority KeyName Variants
784c076c-0159-40e0-ac51-2617d1704f21
  • Tešanović, Slavna (2)
Projects

Author's Bibliography

Development of a Flow Injection System for Differential Pulse Amperometry and Its Application for Diazepam Determination

Antunović, Vesna R.; Tešanović, Slavna; Perušković, Danica S.; Stevanović, Nikola R.; Baošić, Rada; Mandić, Snežana D.; Lolić, Aleksandar

(Hindawi Ltd, London, 2018)

TY  - JOUR
AU  - Antunović, Vesna R.
AU  - Tešanović, Slavna
AU  - Perušković, Danica S.
AU  - Stevanović, Nikola R.
AU  - Baošić, Rada
AU  - Mandić, Snežana D.
AU  - Lolić, Aleksandar
PY  - 2018
UR  - https://cherry.chem.bg.ac.rs/handle/123456789/2122
AB  - The is work presents the development of a flow injection system for differential pulse amperometry (DPA) for diazepam determination in the presence of oxygen. The thin flow cell consisted of the bare glassy carbon electrode, reference silver/silver chloride, and stainless steel as the auxiliary electrode. Electrochemical reduction of diazepam (DZP) was characterised by cyclic voltammetry. Azomethine reduction peak was used for DZP quantification. The detector response was linear in the range 20-250 mu mol/dm(3) of diazepam, with a calculated detection limit of 3.83 mu g/cm(3). Intraday and interday precision were 1.53 and 10.8%, respectively. The method was applied on three beverage samples, energetic drink, and two different beer samples, and obtained recoveries were from 93.65 up to 104.96%. The throughoutput of the method was up to 90 analyses per hour.
PB  - Hindawi Ltd, London
T2  - Journal of Analytical Methods in Chemistry
T1  - Development of a Flow Injection System for Differential Pulse Amperometry and Its Application for Diazepam Determination
DO  - 10.1155/2018/6121489
ER  - 
@article{
author = "Antunović, Vesna R. and Tešanović, Slavna and Perušković, Danica S. and Stevanović, Nikola R. and Baošić, Rada and Mandić, Snežana D. and Lolić, Aleksandar",
year = "2018",
abstract = "The is work presents the development of a flow injection system for differential pulse amperometry (DPA) for diazepam determination in the presence of oxygen. The thin flow cell consisted of the bare glassy carbon electrode, reference silver/silver chloride, and stainless steel as the auxiliary electrode. Electrochemical reduction of diazepam (DZP) was characterised by cyclic voltammetry. Azomethine reduction peak was used for DZP quantification. The detector response was linear in the range 20-250 mu mol/dm(3) of diazepam, with a calculated detection limit of 3.83 mu g/cm(3). Intraday and interday precision were 1.53 and 10.8%, respectively. The method was applied on three beverage samples, energetic drink, and two different beer samples, and obtained recoveries were from 93.65 up to 104.96%. The throughoutput of the method was up to 90 analyses per hour.",
publisher = "Hindawi Ltd, London",
journal = "Journal of Analytical Methods in Chemistry",
title = "Development of a Flow Injection System for Differential Pulse Amperometry and Its Application for Diazepam Determination",
doi = "10.1155/2018/6121489"
}
Antunović, V. R., Tešanović, S., Perušković, D. S., Stevanović, N. R., Baošić, R., Mandić, S. D.,& Lolić, A.. (2018). Development of a Flow Injection System for Differential Pulse Amperometry and Its Application for Diazepam Determination. in Journal of Analytical Methods in Chemistry
Hindawi Ltd, London..
https://doi.org/10.1155/2018/6121489
Antunović VR, Tešanović S, Perušković DS, Stevanović NR, Baošić R, Mandić SD, Lolić A. Development of a Flow Injection System for Differential Pulse Amperometry and Its Application for Diazepam Determination. in Journal of Analytical Methods in Chemistry. 2018;.
doi:10.1155/2018/6121489 .
Antunović, Vesna R., Tešanović, Slavna, Perušković, Danica S., Stevanović, Nikola R., Baošić, Rada, Mandić, Snežana D., Lolić, Aleksandar, "Development of a Flow Injection System for Differential Pulse Amperometry and Its Application for Diazepam Determination" in Journal of Analytical Methods in Chemistry (2018),
https://doi.org/10.1155/2018/6121489 . .
5
3
4

Determination of diazepam by flow-injection with amperometric detection in beverages

Lolić, Aleksandar; Antunović, Vesna R.; Tešanović, Slavna; Perušković, Danica S.; Stevanović, Nikola R.; Baošić, Rada; Nikolić, Snežana

(ISEP Instituto Superior de Engenharia do Porto, 2016)

TY  - CONF
AU  - Lolić, Aleksandar
AU  - Antunović, Vesna R.
AU  - Tešanović, Slavna
AU  - Perušković, Danica S.
AU  - Stevanović, Nikola R.
AU  - Baošić, Rada
AU  - Nikolić, Snežana
PY  - 2016
UR  - http://cherry.chem.bg.ac.rs/handle/123456789/4994
AB  - Diazepam belongs to the group of benzodiazepine drugs, and its consumption with alcohol enhances its sedative effect and absorption rate. That is why it is often used as “date rape drug” [1]. In our experiments we applied the flow injection system on diazepam determination on a bare glassy carbon electrode. The electrochemical determination of diazepam is based on reduction of the azomethine group yielding a dyhidrodiazepam. The single cathodic peak is caused by the reduction of diazepam by a two electron change. The reduction potential is highly dependent on pH value of the electrolyte, shifting to more negative potentials with higher pH [2].
PB  - ISEP Instituto Superior de Engenharia do Porto
C3  - 1st workshop on Electrochemistry Devices (Bio)Sensors, October 13-14, 2016, Porto, Portugal, Book of Abstracts pp 31
T1  - Determination of diazepam by flow-injection with amperometric detection in beverages
SP  - 37
EP  - 37
UR  - https://hdl.handle.net/21.15107/rcub_cherry_4994
ER  - 
@conference{
author = "Lolić, Aleksandar and Antunović, Vesna R. and Tešanović, Slavna and Perušković, Danica S. and Stevanović, Nikola R. and Baošić, Rada and Nikolić, Snežana",
year = "2016",
abstract = "Diazepam belongs to the group of benzodiazepine drugs, and its consumption with alcohol enhances its sedative effect and absorption rate. That is why it is often used as “date rape drug” [1]. In our experiments we applied the flow injection system on diazepam determination on a bare glassy carbon electrode. The electrochemical determination of diazepam is based on reduction of the azomethine group yielding a dyhidrodiazepam. The single cathodic peak is caused by the reduction of diazepam by a two electron change. The reduction potential is highly dependent on pH value of the electrolyte, shifting to more negative potentials with higher pH [2].",
publisher = "ISEP Instituto Superior de Engenharia do Porto",
journal = "1st workshop on Electrochemistry Devices (Bio)Sensors, October 13-14, 2016, Porto, Portugal, Book of Abstracts pp 31",
title = "Determination of diazepam by flow-injection with amperometric detection in beverages",
pages = "37-37",
url = "https://hdl.handle.net/21.15107/rcub_cherry_4994"
}
Lolić, A., Antunović, V. R., Tešanović, S., Perušković, D. S., Stevanović, N. R., Baošić, R.,& Nikolić, S.. (2016). Determination of diazepam by flow-injection with amperometric detection in beverages. in 1st workshop on Electrochemistry Devices (Bio)Sensors, October 13-14, 2016, Porto, Portugal, Book of Abstracts pp 31
ISEP Instituto Superior de Engenharia do Porto., 37-37.
https://hdl.handle.net/21.15107/rcub_cherry_4994
Lolić A, Antunović VR, Tešanović S, Perušković DS, Stevanović NR, Baošić R, Nikolić S. Determination of diazepam by flow-injection with amperometric detection in beverages. in 1st workshop on Electrochemistry Devices (Bio)Sensors, October 13-14, 2016, Porto, Portugal, Book of Abstracts pp 31. 2016;:37-37.
https://hdl.handle.net/21.15107/rcub_cherry_4994 .
Lolić, Aleksandar, Antunović, Vesna R., Tešanović, Slavna, Perušković, Danica S., Stevanović, Nikola R., Baošić, Rada, Nikolić, Snežana, "Determination of diazepam by flow-injection with amperometric detection in beverages" in 1st workshop on Electrochemistry Devices (Bio)Sensors, October 13-14, 2016, Porto, Portugal, Book of Abstracts pp 31 (2016):37-37,
https://hdl.handle.net/21.15107/rcub_cherry_4994 .