2 in 1 versus 1 plus 1 – Outcomes of the transformation of adsorptive stripping method for the Ni2+ and Co2+ determination

Pastor, Ferenc T.; Dojčinović, Biljana P.; Kodranov, Igor D.; Gorjanović, Stanislava; Ivanović, Tijana; Popović, Daniela Ž.; Miladinović, Jelena

TY  - JOUR
AU  - Pastor, Ferenc T.
AU  - Dojčinović, Biljana P.
AU  - Kodranov, Igor D.
AU  - Gorjanović, Stanislava
AU  - Ivanović, Tijana
AU  - Popović, Daniela Ž.
AU  - Miladinović, Jelena
UR  - http://cherry.chem.bg.ac.rs/handle/123456789/6390
AB  - Due to the similar chemical properties of Ni2+ and Co2+, several dozens of adsorptive stripping voltammetric (AdSV) methods have been developed for their simultaneous determination. The question was would there be some benefits if a stripping method made for simultaneous determination of Ni2+ and Co2+ will be optimized for the determination of only one of them (Ni2+). It was found that the optimized method has for an order of magnitude lower LOQ (1.89×10−10 M), an order of magnitude lower influence of Co2+, and the applicability of one calibration line for four orders of magnitude of Ni2+ concentration. The influence of some common anions and cations has been examined. The developed method was successfully applied for nickel content determination in real samples. The suitability of the developed method for the determination of Co2+ from the same solution in the second run, upon optimizations of deposition potential and time, was also explored. The LOQ obtained for Co2+ (3.61×10−11 M) is almost two orders of magnitude lower than LOQ of the method for simultaneous determination of both cations and, its LOD and LOQ are among few lowest obtained by AdSV methods for Co2+ determination. The developed method for Ni2+ and Co2+ determination from the same solution in two successive runs has significantly better analytical performances than the starting method for their simultaneous determination in one run.
PB  - Wiley
T2  - Electroanalysis
T1  - 2 in 1 versus 1 plus 1 – Outcomes of the transformation of adsorptive stripping method for the Ni2+ and Co2+ determination
VL  - n/a
IS  - n/a
SP  - e202300259
DO  - 10.1002/elan.202300259
ER  - 
@article{
author = "Pastor, Ferenc T. and Dojčinović, Biljana P. and Kodranov, Igor D. and Gorjanović, Stanislava and Ivanović, Tijana and Popović, Daniela Ž. and Miladinović, Jelena",
abstract = "Due to the similar chemical properties of Ni2+ and Co2+, several dozens of adsorptive stripping voltammetric (AdSV) methods have been developed for their simultaneous determination. The question was would there be some benefits if a stripping method made for simultaneous determination of Ni2+ and Co2+ will be optimized for the determination of only one of them (Ni2+). It was found that the optimized method has for an order of magnitude lower LOQ (1.89×10−10 M), an order of magnitude lower influence of Co2+, and the applicability of one calibration line for four orders of magnitude of Ni2+ concentration. The influence of some common anions and cations has been examined. The developed method was successfully applied for nickel content determination in real samples. The suitability of the developed method for the determination of Co2+ from the same solution in the second run, upon optimizations of deposition potential and time, was also explored. The LOQ obtained for Co2+ (3.61×10−11 M) is almost two orders of magnitude lower than LOQ of the method for simultaneous determination of both cations and, its LOD and LOQ are among few lowest obtained by AdSV methods for Co2+ determination. The developed method for Ni2+ and Co2+ determination from the same solution in two successive runs has significantly better analytical performances than the starting method for their simultaneous determination in one run.",
publisher = "Wiley",
journal = "Electroanalysis",
title = "2 in 1 versus 1 plus 1 – Outcomes of the transformation of adsorptive stripping method for the Ni2+ and Co2+ determination",
volume = "n/a",
number = "n/a",
pages = "e202300259",
doi = "10.1002/elan.202300259"
}
Pastor, F. T., Dojčinović, B. P., Kodranov, I. D., Gorjanović, S., Ivanović, T., Popović, D. Ž.,& Miladinović, J..2 in 1 versus 1 plus 1 – Outcomes of the transformation of adsorptive stripping method for the Ni2+ and Co2+ determination. in Electroanalysis
Wiley., n/a(n/a), e202300259.
https://doi.org/10.1002/elan.202300259
Pastor FT, Dojčinović BP, Kodranov ID, Gorjanović S, Ivanović T, Popović DŽ, Miladinović J. 2 in 1 versus 1 plus 1 – Outcomes of the transformation of adsorptive stripping method for the Ni2+ and Co2+ determination. in Electroanalysis.n/a(n/a):e202300259.
doi:10.1002/elan.202300259 .
Pastor, Ferenc T., Dojčinović, Biljana P., Kodranov, Igor D., Gorjanović, Stanislava, Ivanović, Tijana, Popović, Daniela Ž., Miladinović, Jelena, "2 in 1 versus 1 plus 1 – Outcomes of the transformation of adsorptive stripping method for the Ni2+ and Co2+ determination" in Electroanalysis, n/a, no. n/a:e202300259,
https://doi.org/10.1002/elan.202300259 . .
1

Activity Coefficients of the System {yKCl + (1 – y)KH2PO4}(aq) at T = 298.15 K Determined by Cell Potential Measurements

Ivanović, Tijana; Popović, Daniela Ž.; Miladinović, Jelena; Miladinović, Zoran P.; Pastor, Ferenc

(American Chemical Society, 2023)

TY  - JOUR
AU  - Ivanović, Tijana
AU  - Popović, Daniela Ž.
AU  - Miladinović, Jelena
AU  - Miladinović, Zoran P.
AU  - Pastor, Ferenc
PY  - 2023
UR  - http://cherry.chem.bg.ac.rs/handle/123456789/6090
AB  - Zero-current cell potential measurements were used to determine the solution activity coefficient in a ternary system {yKCl + (1 – y) KH2PO4}(aq) at temperature T = 298.15 K. The cell of the type K–ISE|KCl(mKCl), KH2PO4(mKH2PO4)|Ag|AgCl was used in the total ionic strength range, Im = 0.0886–1.0046 mol kg–1. In order to generate a set of parameters that can be applied in a wide range of mixed solution ionic strengths, the Pitzer, Scatchard, and Clegg–Pitzer–Brimblecombe models were used to fit all available experimental data, including cell potential and isopiestic measurements from the literature. The experimental and calculated values of thermodynamic properties for the studied system are in excellent agreement. Potential interactions and solution structure were discussed by means of the excess free energy of mixing via potential pairs, triplets, or quads for the investigated solution using the Scatchard model mixing parameters.
PB  - American Chemical Society
T2  - Journal of Chemical & Engineering Data
T1  - Activity Coefficients of the System {yKCl + (1 – y)KH2PO4}(aq) at T = 298.15 K Determined by Cell Potential Measurements
VL  - 68
IS  - 2
SP  - 405
EP  - 415
DO  - 10.1021/acs.jced.2c00704
ER  - 
@article{
author = "Ivanović, Tijana and Popović, Daniela Ž. and Miladinović, Jelena and Miladinović, Zoran P. and Pastor, Ferenc",
year = "2023",
abstract = "Zero-current cell potential measurements were used to determine the solution activity coefficient in a ternary system {yKCl + (1 – y) KH2PO4}(aq) at temperature T = 298.15 K. The cell of the type K–ISE|KCl(mKCl), KH2PO4(mKH2PO4)|Ag|AgCl was used in the total ionic strength range, Im = 0.0886–1.0046 mol kg–1. In order to generate a set of parameters that can be applied in a wide range of mixed solution ionic strengths, the Pitzer, Scatchard, and Clegg–Pitzer–Brimblecombe models were used to fit all available experimental data, including cell potential and isopiestic measurements from the literature. The experimental and calculated values of thermodynamic properties for the studied system are in excellent agreement. Potential interactions and solution structure were discussed by means of the excess free energy of mixing via potential pairs, triplets, or quads for the investigated solution using the Scatchard model mixing parameters.",
publisher = "American Chemical Society",
journal = "Journal of Chemical & Engineering Data",
title = "Activity Coefficients of the System {yKCl + (1 – y)KH2PO4}(aq) at T = 298.15 K Determined by Cell Potential Measurements",
volume = "68",
number = "2",
pages = "405-415",
doi = "10.1021/acs.jced.2c00704"
}
Ivanović, T., Popović, D. Ž., Miladinović, J., Miladinović, Z. P.,& Pastor, F.. (2023). Activity Coefficients of the System {yKCl + (1 – y)KH2PO4}(aq) at T = 298.15 K Determined by Cell Potential Measurements. in Journal of Chemical & Engineering Data
American Chemical Society., 68(2), 405-415.
https://doi.org/10.1021/acs.jced.2c00704
Ivanović T, Popović DŽ, Miladinović J, Miladinović ZP, Pastor F. Activity Coefficients of the System {yKCl + (1 – y)KH2PO4}(aq) at T = 298.15 K Determined by Cell Potential Measurements. in Journal of Chemical & Engineering Data. 2023;68(2):405-415.
doi:10.1021/acs.jced.2c00704 .
Ivanović, Tijana, Popović, Daniela Ž., Miladinović, Jelena, Miladinović, Zoran P., Pastor, Ferenc, "Activity Coefficients of the System {yKCl + (1 – y)KH2PO4}(aq) at T = 298.15 K Determined by Cell Potential Measurements" in Journal of Chemical & Engineering Data, 68, no. 2 (2023):405-415,
https://doi.org/10.1021/acs.jced.2c00704 . .
2
1