Miletić, S.

Link to this page

Authority KeyName Variants
7d5046f1-9df4-4441-bdac-8d3e73c9adc9
  • Miletić, S. (3)
Projects

Author's Bibliography

Soil Contamination by Petroleum Products in the Urban Environments: Belgrade, Serbia

Dević, G.; Ilić, M.; Bulatović, S.; Miletić, S.

(Belgrade : Serbian Chemical Society, 2021)

TY  - CONF
AU  - Dević, G.
AU  - Ilić, M.
AU  - Bulatović, S.
AU  - Miletić, S.
PY  - 2021
UR  - http://cherry.chem.bg.ac.rs/handle/123456789/4928
AB  - Environmental pollution with petroleum and petrochemical products has attracted much attention in recent years. The present study is focused on the investigation of urban soil pollution in the area of thermal plant New Belgrade with more than 200000 residents. Thermal Power Plant New Belgrade is located on the left bank of the Sava, about 1 km from the Sava’s confluence with the Danube. The Thermal Power Plant complex consists of storage tanks for crude oil and oil products and it was contaminated due to break-down of the mazut reservoirs (2009, during a gas crisis) and NATO bombing of the reservoirs (1999). A total of 45 soil samples were collected in May, 2015, and in total 8 geochemical parameters were determined by using official or recommended methods [1]. Statistical data processing includes application of multivariate statistical methods to previously systematized data on geochemical parameters in soil samples from Belgrade city. Two multivariate statistical methods have been applied – hierarchical cluster analysis (HCA) and factor analysis – analysis of the main components (PCA). From the output of the hierarchical cluster analysis, a total of three clusters of the soil samples were recognized according to the level of clustering. Cluster A and B are linked at a shorter distance and are together linked to Cluster C at a longer distance. Component 1 of the PCA dominated in group A. Samples of group A contained the maximum amounts of total aliphatic hydrocarbon (TPH) (71.85±17.9), and Unresolved/Resolved complex mixture (U/R) (3.02±1.8) higher than the other groups. The results of the soil analyses indicated that most samples classified as C1 may reflect anthropogenic contamination of the urban environment. The results showed that the top soil contained high concentration of TPH (90.65 mg kg−1). This may be a result was caused by crude oil spills and leaks which continuously occured for long periods of time. According to the “Regulation on the program of systematic monitoring of land quality, indicators for According to the “Regulation on the program of systematic monitoring of land quality, indicators for assessment of the risk of land degradation and the methodology for making remediation programs “(Official Gazette of RS, No. 88/2010-Annex 13) are not higher than” values that may indicate significant contamination “-remediation values, but are higher than ”limit values“, which means that this area must be programs “(Official Gazette of RS, No. 88/2010-Annex 13)) are not higher than” values that may indicate significant contamination “-remediation values, but are higher than” limit values “, which means that this area must be under permanently monitoring. Group B is represented by a principal component 2 related to the highest CPI (3.48±1.32), Low/High alkanes (0.299±0.45), and ACL (the average number of carbon atoms per molecule based on the abundance of odd-carbon-numbered higher plant n-alkanes) (29.67±0.40). The analyzed samples have similar ACL contents in all groups. Distribution of these parameters suggesting predominant biogenic sources rather than petroleum related input. The component 3 of the PCA2, loaded by n-C17/ Pr, and n-C18/Phy, also constituted a strong cluster C, n-C17 and n-C18 are more abundant than the isoprenoids pristane and phytane. Comparatively, isoprenoid hydrocarbons are more resistant to biodegradation than n-alkanes [2], leading to the increase of Pr/ n-C17 and Ph/n-C18 ratios to a value of much higher than 1 when they have been deeply degraded [3]. The distribution of Pr/n-C17, and Ph/n-C18 ratios for almost all samples are small than 1, indicate biogenic contribution, except of some samples are around 1, points to petroleum contamination source in urban area of Belgrade city.
PB  - Belgrade : Serbian Chemical Society
C3  - Book of Abstracts 21st; European Meeting on Environmental Chemistry
T1  - Soil Contamination by Petroleum Products in the Urban Environments: Belgrade, Serbia
SP  - 156
EP  - 156
UR  - https://hdl.handle.net/21.15107/rcub_cherry_4928
ER  - 
@conference{
author = "Dević, G. and Ilić, M. and Bulatović, S. and Miletić, S.",
year = "2021",
abstract = "Environmental pollution with petroleum and petrochemical products has attracted much attention in recent years. The present study is focused on the investigation of urban soil pollution in the area of thermal plant New Belgrade with more than 200000 residents. Thermal Power Plant New Belgrade is located on the left bank of the Sava, about 1 km from the Sava’s confluence with the Danube. The Thermal Power Plant complex consists of storage tanks for crude oil and oil products and it was contaminated due to break-down of the mazut reservoirs (2009, during a gas crisis) and NATO bombing of the reservoirs (1999). A total of 45 soil samples were collected in May, 2015, and in total 8 geochemical parameters were determined by using official or recommended methods [1]. Statistical data processing includes application of multivariate statistical methods to previously systematized data on geochemical parameters in soil samples from Belgrade city. Two multivariate statistical methods have been applied – hierarchical cluster analysis (HCA) and factor analysis – analysis of the main components (PCA). From the output of the hierarchical cluster analysis, a total of three clusters of the soil samples were recognized according to the level of clustering. Cluster A and B are linked at a shorter distance and are together linked to Cluster C at a longer distance. Component 1 of the PCA dominated in group A. Samples of group A contained the maximum amounts of total aliphatic hydrocarbon (TPH) (71.85±17.9), and Unresolved/Resolved complex mixture (U/R) (3.02±1.8) higher than the other groups. The results of the soil analyses indicated that most samples classified as C1 may reflect anthropogenic contamination of the urban environment. The results showed that the top soil contained high concentration of TPH (90.65 mg kg−1). This may be a result was caused by crude oil spills and leaks which continuously occured for long periods of time. According to the “Regulation on the program of systematic monitoring of land quality, indicators for According to the “Regulation on the program of systematic monitoring of land quality, indicators for assessment of the risk of land degradation and the methodology for making remediation programs “(Official Gazette of RS, No. 88/2010-Annex 13) are not higher than” values that may indicate significant contamination “-remediation values, but are higher than ”limit values“, which means that this area must be programs “(Official Gazette of RS, No. 88/2010-Annex 13)) are not higher than” values that may indicate significant contamination “-remediation values, but are higher than” limit values “, which means that this area must be under permanently monitoring. Group B is represented by a principal component 2 related to the highest CPI (3.48±1.32), Low/High alkanes (0.299±0.45), and ACL (the average number of carbon atoms per molecule based on the abundance of odd-carbon-numbered higher plant n-alkanes) (29.67±0.40). The analyzed samples have similar ACL contents in all groups. Distribution of these parameters suggesting predominant biogenic sources rather than petroleum related input. The component 3 of the PCA2, loaded by n-C17/ Pr, and n-C18/Phy, also constituted a strong cluster C, n-C17 and n-C18 are more abundant than the isoprenoids pristane and phytane. Comparatively, isoprenoid hydrocarbons are more resistant to biodegradation than n-alkanes [2], leading to the increase of Pr/ n-C17 and Ph/n-C18 ratios to a value of much higher than 1 when they have been deeply degraded [3]. The distribution of Pr/n-C17, and Ph/n-C18 ratios for almost all samples are small than 1, indicate biogenic contribution, except of some samples are around 1, points to petroleum contamination source in urban area of Belgrade city.",
publisher = "Belgrade : Serbian Chemical Society",
journal = "Book of Abstracts 21st; European Meeting on Environmental Chemistry",
title = "Soil Contamination by Petroleum Products in the Urban Environments: Belgrade, Serbia",
pages = "156-156",
url = "https://hdl.handle.net/21.15107/rcub_cherry_4928"
}
Dević, G., Ilić, M., Bulatović, S.,& Miletić, S.. (2021). Soil Contamination by Petroleum Products in the Urban Environments: Belgrade, Serbia. in Book of Abstracts 21st; European Meeting on Environmental Chemistry
Belgrade : Serbian Chemical Society., 156-156.
https://hdl.handle.net/21.15107/rcub_cherry_4928
Dević G, Ilić M, Bulatović S, Miletić S. Soil Contamination by Petroleum Products in the Urban Environments: Belgrade, Serbia. in Book of Abstracts 21st; European Meeting on Environmental Chemistry. 2021;:156-156.
https://hdl.handle.net/21.15107/rcub_cherry_4928 .
Dević, G., Ilić, M., Bulatović, S., Miletić, S., "Soil Contamination by Petroleum Products in the Urban Environments: Belgrade, Serbia" in Book of Abstracts 21st; European Meeting on Environmental Chemistry (2021):156-156,
https://hdl.handle.net/21.15107/rcub_cherry_4928 .

Electrical Characterization of Microbial Fuel Cells-Method and Preliminary Results

Ranđelović, Danijela; Jakšić, O. M.; Popović, B.; Joksimović, Kristina; Miletić, S.; Poljak, P.; Beškoski, Vladimir

(Institute of Electrical and Electronics Engineers Inc., 2019)

TY  - CONF
AU  - Ranđelović, Danijela
AU  - Jakšić, O. M.
AU  - Popović, B.
AU  - Joksimović, Kristina
AU  - Miletić, S.
AU  - Poljak, P.
AU  - Beškoski, Vladimir
PY  - 2019
UR  - https://cherry.chem.bg.ac.rs/handle/123456789/3754
AB  - Microbial fuel cells (MFC) present bioelectrochemical systems that allow generation of electricity during anaerobic respiration of selected bacterial species. They have very promising applications in wastewater purification systems, as biosensors or as alternative power source. This work is a result of joint multidisciplinary research and presents preliminary experimental results obtained by electrical characterization of a single-chamber MFC. The goal of research was to study activity of MFC and estimate its internal resistance.
PB  - Institute of Electrical and Electronics Engineers Inc.
C3  - 2019 IEEE 31st International Conference on Microelectronics, MIEL 2019 - Proceedings
T1  - Electrical Characterization of Microbial Fuel Cells-Method and Preliminary Results
SP  - 321
EP  - 324
DO  - 10.1109/MIEL.2019.8889650
ER  - 
@conference{
author = "Ranđelović, Danijela and Jakšić, O. M. and Popović, B. and Joksimović, Kristina and Miletić, S. and Poljak, P. and Beškoski, Vladimir",
year = "2019",
abstract = "Microbial fuel cells (MFC) present bioelectrochemical systems that allow generation of electricity during anaerobic respiration of selected bacterial species. They have very promising applications in wastewater purification systems, as biosensors or as alternative power source. This work is a result of joint multidisciplinary research and presents preliminary experimental results obtained by electrical characterization of a single-chamber MFC. The goal of research was to study activity of MFC and estimate its internal resistance.",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
journal = "2019 IEEE 31st International Conference on Microelectronics, MIEL 2019 - Proceedings",
title = "Electrical Characterization of Microbial Fuel Cells-Method and Preliminary Results",
pages = "321-324",
doi = "10.1109/MIEL.2019.8889650"
}
Ranđelović, D., Jakšić, O. M., Popović, B., Joksimović, K., Miletić, S., Poljak, P.,& Beškoski, V.. (2019). Electrical Characterization of Microbial Fuel Cells-Method and Preliminary Results. in 2019 IEEE 31st International Conference on Microelectronics, MIEL 2019 - Proceedings
Institute of Electrical and Electronics Engineers Inc.., 321-324.
https://doi.org/10.1109/MIEL.2019.8889650
Ranđelović D, Jakšić OM, Popović B, Joksimović K, Miletić S, Poljak P, Beškoski V. Electrical Characterization of Microbial Fuel Cells-Method and Preliminary Results. in 2019 IEEE 31st International Conference on Microelectronics, MIEL 2019 - Proceedings. 2019;:321-324.
doi:10.1109/MIEL.2019.8889650 .
Ranđelović, Danijela, Jakšić, O. M., Popović, B., Joksimović, Kristina, Miletić, S., Poljak, P., Beškoski, Vladimir, "Electrical Characterization of Microbial Fuel Cells-Method and Preliminary Results" in 2019 IEEE 31st International Conference on Microelectronics, MIEL 2019 - Proceedings (2019):321-324,
https://doi.org/10.1109/MIEL.2019.8889650 . .
3
3

Efficiency of commercial enzymatic preparations in grain hydrolysis for preparation of substrates for beer fermentation

Ivanovska, J.; Mladenovic, S.; Nastasijevic, B.; Miletić, S.; Aćimović, Jelena M.

(Blackwell Publishing, Oxford, 2007)

TY  - CONF
AU  - Ivanovska, J.
AU  - Mladenovic, S.
AU  - Nastasijevic, B.
AU  - Miletić, S.
AU  - Aćimović, Jelena M.
PY  - 2007
UR  - https://cherry.chem.bg.ac.rs/handle/123456789/915
PB  - Blackwell Publishing, Oxford
C3  - FEBS Journal / Federation of European of Biochemical Societies
T1  - Efficiency of commercial enzymatic preparations in grain hydrolysis for preparation of substrates for beer fermentation
VL  - 274
SP  - 224
EP  - 224
UR  - https://hdl.handle.net/21.15107/rcub_cherry_915
ER  - 
@conference{
author = "Ivanovska, J. and Mladenovic, S. and Nastasijevic, B. and Miletić, S. and Aćimović, Jelena M.",
year = "2007",
publisher = "Blackwell Publishing, Oxford",
journal = "FEBS Journal / Federation of European of Biochemical Societies",
title = "Efficiency of commercial enzymatic preparations in grain hydrolysis for preparation of substrates for beer fermentation",
volume = "274",
pages = "224-224",
url = "https://hdl.handle.net/21.15107/rcub_cherry_915"
}
Ivanovska, J., Mladenovic, S., Nastasijevic, B., Miletić, S.,& Aćimović, J. M.. (2007). Efficiency of commercial enzymatic preparations in grain hydrolysis for preparation of substrates for beer fermentation. in FEBS Journal / Federation of European of Biochemical Societies
Blackwell Publishing, Oxford., 274, 224-224.
https://hdl.handle.net/21.15107/rcub_cherry_915
Ivanovska J, Mladenovic S, Nastasijevic B, Miletić S, Aćimović JM. Efficiency of commercial enzymatic preparations in grain hydrolysis for preparation of substrates for beer fermentation. in FEBS Journal / Federation of European of Biochemical Societies. 2007;274:224-224.
https://hdl.handle.net/21.15107/rcub_cherry_915 .
Ivanovska, J., Mladenovic, S., Nastasijevic, B., Miletić, S., Aćimović, Jelena M., "Efficiency of commercial enzymatic preparations in grain hydrolysis for preparation of substrates for beer fermentation" in FEBS Journal / Federation of European of Biochemical Societies, 274 (2007):224-224,
https://hdl.handle.net/21.15107/rcub_cherry_915 .