Švorc, Ľubomir

Link to this page

Authority KeyName Variants
b844dec0-0926-4797-a207-9472a2397a5e
  • Švorc, Ľubomir (2)
Projects
No records found.

Author's Bibliography

Application of bismuth (III) oxide decorated graphene nanoribbons for enzymatic glucose biosensing

Đurđić, Slađana Z.; Vukojević, Vesna; Vlahović, Filip; Ognjanović, Miloš; Švorc, Ľubomir; Kalcher, Kurt; Mutić, Jelena; Stanković, Dalibor

(Elsevier, 2019)

TY  - JOUR
AU  - Đurđić, Slađana Z.
AU  - Vukojević, Vesna
AU  - Vlahović, Filip
AU  - Ognjanović, Miloš
AU  - Švorc, Ľubomir
AU  - Kalcher, Kurt
AU  - Mutić, Jelena
AU  - Stanković, Dalibor
PY  - 2019
UR  - https://cherry.chem.bg.ac.rs/handle/123456789/3751
AB  - In present work we report application of bismuth (III) oxide (Bi2O3) decorated graphene nanoribbons (GNR)
composite for modification of screen printed electrode, and use of resulting modified screen-printed electrode
(SPCE/GNR/Bi2O3) as a disposable glucose biosensor. The composite was synthesized by use of co-precipitation
method followed by ultra-sonication. After characterization, the material was applied on the surface of the
screen-printed electrode in a ‘drop casting’ fashion. Glucose oxidase (GOx) was added to the modified surface
and finally covered by Nafion film. Resulting biosensor electrode (SPCE/GNR/Bi2O3/GOx/Naf) shows excellent
performance toward glucose detection, with working linear range from 0.28 to 1.70 mM and detection limit of
0.07 mM. Prepared biosensor was applied for the estimation of glucose level in standard honey samples with declared glucose level, in order to validate the methods (PT scheme). Obtained results are indicating excellent stability, reproducibility, accuracy and precision of the method for the determination of glucose in such samples
with negligible matrix effect. Developed biosensor showed high precision, accuracy and selectivity even when
employed for determination of glucose content in blood serum and urine samples. Proposed biosensor construction shows promising results and can be considered as stabile and reproducible tool for detection and quantification of glucose in investigated samples.
PB  - Elsevier
T2  - Journal of Electroanalytical Chemistry
T1  - Application of bismuth (III) oxide decorated graphene nanoribbons for enzymatic glucose biosensing
VL  - 850
DO  - 10.1016/j.jelechem.2019.113400
ER  - 
@article{
author = "Đurđić, Slađana Z. and Vukojević, Vesna and Vlahović, Filip and Ognjanović, Miloš and Švorc, Ľubomir and Kalcher, Kurt and Mutić, Jelena and Stanković, Dalibor",
year = "2019",
abstract = "In present work we report application of bismuth (III) oxide (Bi2O3) decorated graphene nanoribbons (GNR)
composite for modification of screen printed electrode, and use of resulting modified screen-printed electrode
(SPCE/GNR/Bi2O3) as a disposable glucose biosensor. The composite was synthesized by use of co-precipitation
method followed by ultra-sonication. After characterization, the material was applied on the surface of the
screen-printed electrode in a ‘drop casting’ fashion. Glucose oxidase (GOx) was added to the modified surface
and finally covered by Nafion film. Resulting biosensor electrode (SPCE/GNR/Bi2O3/GOx/Naf) shows excellent
performance toward glucose detection, with working linear range from 0.28 to 1.70 mM and detection limit of
0.07 mM. Prepared biosensor was applied for the estimation of glucose level in standard honey samples with declared glucose level, in order to validate the methods (PT scheme). Obtained results are indicating excellent stability, reproducibility, accuracy and precision of the method for the determination of glucose in such samples
with negligible matrix effect. Developed biosensor showed high precision, accuracy and selectivity even when
employed for determination of glucose content in blood serum and urine samples. Proposed biosensor construction shows promising results and can be considered as stabile and reproducible tool for detection and quantification of glucose in investigated samples.",
publisher = "Elsevier",
journal = "Journal of Electroanalytical Chemistry",
title = "Application of bismuth (III) oxide decorated graphene nanoribbons for enzymatic glucose biosensing",
volume = "850",
doi = "10.1016/j.jelechem.2019.113400"
}
Đurđić, S. Z., Vukojević, V., Vlahović, F., Ognjanović, M., Švorc, Ľ., Kalcher, K., Mutić, J.,& Stanković, D.. (2019). Application of bismuth (III) oxide decorated graphene nanoribbons for enzymatic glucose biosensing. in Journal of Electroanalytical Chemistry
Elsevier., 850.
https://doi.org/10.1016/j.jelechem.2019.113400
Đurđić SZ, Vukojević V, Vlahović F, Ognjanović M, Švorc Ľ, Kalcher K, Mutić J, Stanković D. Application of bismuth (III) oxide decorated graphene nanoribbons for enzymatic glucose biosensing. in Journal of Electroanalytical Chemistry. 2019;850.
doi:10.1016/j.jelechem.2019.113400 .
Đurđić, Slađana Z., Vukojević, Vesna, Vlahović, Filip, Ognjanović, Miloš, Švorc, Ľubomir, Kalcher, Kurt, Mutić, Jelena, Stanković, Dalibor, "Application of bismuth (III) oxide decorated graphene nanoribbons for enzymatic glucose biosensing" in Journal of Electroanalytical Chemistry, 850 (2019),
https://doi.org/10.1016/j.jelechem.2019.113400 . .
29
16
29
28

Supplementary data for article: Đurđić, S.; Vukojević, V.; Vlahović, F.; Ognjanović, M.; Švorc; Kalcher, K.; Mutić, J.; Stanković, D. M. Application of Bismuth (III) Oxide Decorated Graphene Nanoribbons for Enzymatic Glucose Biosensing. Journal of Electroanalytical Chemistry 2019, 850. https://doi.org/10.1016/j.jelechem.2019.113400

Đurđić, Slađana Z.; Vukojević, Vesna; Vlahović, Filip; Ognjanović, Miloš; Švorc, Ľubomir; Kalcher, Kurt; Mutić, Jelena; Stanković, Dalibor

(Elsevier, 2019)

TY  - DATA
AU  - Đurđić, Slađana Z.
AU  - Vukojević, Vesna
AU  - Vlahović, Filip
AU  - Ognjanović, Miloš
AU  - Švorc, Ľubomir
AU  - Kalcher, Kurt
AU  - Mutić, Jelena
AU  - Stanković, Dalibor
PY  - 2019
UR  - https://cherry.chem.bg.ac.rs/handle/123456789/3752
PB  - Elsevier
T2  - Journal of Electroanalytical Chemistry
T1  - Supplementary data for article: Đurđić, S.; Vukojević, V.; Vlahović, F.; Ognjanović, M.; Švorc; Kalcher, K.; Mutić, J.; Stanković, D. M. Application of Bismuth (III) Oxide Decorated Graphene Nanoribbons for Enzymatic Glucose Biosensing. Journal of Electroanalytical Chemistry 2019, 850. https://doi.org/10.1016/j.jelechem.2019.113400
UR  - https://hdl.handle.net/21.15107/rcub_cherry_3752
ER  - 
@misc{
author = "Đurđić, Slađana Z. and Vukojević, Vesna and Vlahović, Filip and Ognjanović, Miloš and Švorc, Ľubomir and Kalcher, Kurt and Mutić, Jelena and Stanković, Dalibor",
year = "2019",
publisher = "Elsevier",
journal = "Journal of Electroanalytical Chemistry",
title = "Supplementary data for article: Đurđić, S.; Vukojević, V.; Vlahović, F.; Ognjanović, M.; Švorc; Kalcher, K.; Mutić, J.; Stanković, D. M. Application of Bismuth (III) Oxide Decorated Graphene Nanoribbons for Enzymatic Glucose Biosensing. Journal of Electroanalytical Chemistry 2019, 850. https://doi.org/10.1016/j.jelechem.2019.113400",
url = "https://hdl.handle.net/21.15107/rcub_cherry_3752"
}
Đurđić, S. Z., Vukojević, V., Vlahović, F., Ognjanović, M., Švorc, Ľ., Kalcher, K., Mutić, J.,& Stanković, D.. (2019). Supplementary data for article: Đurđić, S.; Vukojević, V.; Vlahović, F.; Ognjanović, M.; Švorc; Kalcher, K.; Mutić, J.; Stanković, D. M. Application of Bismuth (III) Oxide Decorated Graphene Nanoribbons for Enzymatic Glucose Biosensing. Journal of Electroanalytical Chemistry 2019, 850. https://doi.org/10.1016/j.jelechem.2019.113400. in Journal of Electroanalytical Chemistry
Elsevier..
https://hdl.handle.net/21.15107/rcub_cherry_3752
Đurđić SZ, Vukojević V, Vlahović F, Ognjanović M, Švorc Ľ, Kalcher K, Mutić J, Stanković D. Supplementary data for article: Đurđić, S.; Vukojević, V.; Vlahović, F.; Ognjanović, M.; Švorc; Kalcher, K.; Mutić, J.; Stanković, D. M. Application of Bismuth (III) Oxide Decorated Graphene Nanoribbons for Enzymatic Glucose Biosensing. Journal of Electroanalytical Chemistry 2019, 850. https://doi.org/10.1016/j.jelechem.2019.113400. in Journal of Electroanalytical Chemistry. 2019;.
https://hdl.handle.net/21.15107/rcub_cherry_3752 .
Đurđić, Slađana Z., Vukojević, Vesna, Vlahović, Filip, Ognjanović, Miloš, Švorc, Ľubomir, Kalcher, Kurt, Mutić, Jelena, Stanković, Dalibor, "Supplementary data for article: Đurđić, S.; Vukojević, V.; Vlahović, F.; Ognjanović, M.; Švorc; Kalcher, K.; Mutić, J.; Stanković, D. M. Application of Bismuth (III) Oxide Decorated Graphene Nanoribbons for Enzymatic Glucose Biosensing. Journal of Electroanalytical Chemistry 2019, 850. https://doi.org/10.1016/j.jelechem.2019.113400" in Journal of Electroanalytical Chemistry (2019),
https://hdl.handle.net/21.15107/rcub_cherry_3752 .