Tripkovic, Tatjana

Link to this page

Authority KeyName Variants
6a9e1b47-501a-4359-b1cc-6403873f8c65
  • Tripkovic, Tatjana (3)
Projects

Author's Bibliography

Electrochemical behavior and antioxidant activity of tetradentate Schiff bases and their copper(II) complexes

Aburas, Najat M.; Lolić, Aleksandar; Stevanović, Nikola R.; Tripkovic, Tatjana; Nikolić-Mandić, Snežana D.; Baošić, Rada

(Springer, New York, 2012)

TY  - JOUR
AU  - Aburas, Najat M.
AU  - Lolić, Aleksandar
AU  - Stevanović, Nikola R.
AU  - Tripkovic, Tatjana
AU  - Nikolić-Mandić, Snežana D.
AU  - Baošić, Rada
PY  - 2012
UR  - https://cherry.chem.bg.ac.rs/handle/123456789/1547
AB  - This study describes the effects of the substituents on electrochemical behavior and antioxidant activity of the six tetradentate Schiff bases, containing ethane-1,2-diamine or propane-1,2-diamine as the amine part and pentane-2,4-dione and/or 1-phenylbutane-1,3-dione as beta-diketone, and corresponding copper(II) complexes. Cyclic voltammograms of these compounds were recorded in dimethylsulfoxide and 0.1 M sodium perchlorate as supporting electrolyte with glassy carbon as working electrode at different scan rates. The voltammograms of Schiff bases alone showed only one irreversible peak. Voltammograms recorded for complexes showed the presence of quasi-reversible processes taking place at the metal center and reversible process at the ligand part. Both steric and inductive effects of substituents and structure of imine bridge of Schiff base ligands as well as complexes were discussed. These effects appear relevant for the antioxidant activity. Antioxidant activity of the investigated compounds expressed as Trolox equivalent antioxidant capacity is also discussed. The electrochemical behavior showed a high correlation with the antioxidant activity for investigated compounds.
PB  - Springer, New York
T2  - Journal of the Iranian Chemical Society
T1  - Electrochemical behavior and antioxidant activity of tetradentate Schiff bases and their copper(II) complexes
VL  - 9
IS  - 6
SP  - 859
EP  - 864
DO  - 10.1007/s13738-012-0102-7
ER  - 
@article{
author = "Aburas, Najat M. and Lolić, Aleksandar and Stevanović, Nikola R. and Tripkovic, Tatjana and Nikolić-Mandić, Snežana D. and Baošić, Rada",
year = "2012",
abstract = "This study describes the effects of the substituents on electrochemical behavior and antioxidant activity of the six tetradentate Schiff bases, containing ethane-1,2-diamine or propane-1,2-diamine as the amine part and pentane-2,4-dione and/or 1-phenylbutane-1,3-dione as beta-diketone, and corresponding copper(II) complexes. Cyclic voltammograms of these compounds were recorded in dimethylsulfoxide and 0.1 M sodium perchlorate as supporting electrolyte with glassy carbon as working electrode at different scan rates. The voltammograms of Schiff bases alone showed only one irreversible peak. Voltammograms recorded for complexes showed the presence of quasi-reversible processes taking place at the metal center and reversible process at the ligand part. Both steric and inductive effects of substituents and structure of imine bridge of Schiff base ligands as well as complexes were discussed. These effects appear relevant for the antioxidant activity. Antioxidant activity of the investigated compounds expressed as Trolox equivalent antioxidant capacity is also discussed. The electrochemical behavior showed a high correlation with the antioxidant activity for investigated compounds.",
publisher = "Springer, New York",
journal = "Journal of the Iranian Chemical Society",
title = "Electrochemical behavior and antioxidant activity of tetradentate Schiff bases and their copper(II) complexes",
volume = "9",
number = "6",
pages = "859-864",
doi = "10.1007/s13738-012-0102-7"
}
Aburas, N. M., Lolić, A., Stevanović, N. R., Tripkovic, T., Nikolić-Mandić, S. D.,& Baošić, R.. (2012). Electrochemical behavior and antioxidant activity of tetradentate Schiff bases and their copper(II) complexes. in Journal of the Iranian Chemical Society
Springer, New York., 9(6), 859-864.
https://doi.org/10.1007/s13738-012-0102-7
Aburas NM, Lolić A, Stevanović NR, Tripkovic T, Nikolić-Mandić SD, Baošić R. Electrochemical behavior and antioxidant activity of tetradentate Schiff bases and their copper(II) complexes. in Journal of the Iranian Chemical Society. 2012;9(6):859-864.
doi:10.1007/s13738-012-0102-7 .
Aburas, Najat M., Lolić, Aleksandar, Stevanović, Nikola R., Tripkovic, Tatjana, Nikolić-Mandić, Snežana D., Baošić, Rada, "Electrochemical behavior and antioxidant activity of tetradentate Schiff bases and their copper(II) complexes" in Journal of the Iranian Chemical Society, 9, no. 6 (2012):859-864,
https://doi.org/10.1007/s13738-012-0102-7 . .
3
11
9
12
9

Development of a flow injection method with amperometric detection for the indirect determination of copper in drinking water samples

Lolić, Aleksandar; Tripkovic, Tatjana; Baošić, Rada; Nikolić-Mandić, Snežana D.; Stanimirović, Bojana

(Serbian Chemical Soc, Belgrade, 2012)

TY  - JOUR
AU  - Lolić, Aleksandar
AU  - Tripkovic, Tatjana
AU  - Baošić, Rada
AU  - Nikolić-Mandić, Snežana D.
AU  - Stanimirović, Bojana
PY  - 2012
UR  - https://cherry.chem.bg.ac.rs/handle/123456789/1569
AB  - A gas-diffusion flow injection method with amperometric detection for the indirect determination of copper on a silver electrode was developed. The flow through system was equipped with two injection valves and a gas-diffusion unit. In the first step, a signal of a cyanide solution was recorded. In the subsequent step, the signal of cyanide in the presence of copper was measured. Interferences (Cd(II), Co(II), Ag(I), Ni(II), Fe(III), Hg(II) and Zn(II)) were investigated and successfully removed. The calibration graph was linear in the range 1-90 mu mol dm(-3) of copper with a correlation coefficient of 0.993. The regression equation is I = (0.0455 +/- 0.0015)c + (0.4611 +/- 0.0671), where I is the relative signal decrease in mu A and c is concentration in mu mol dm(-3). Relative standard deviation for six consecutive injections of 30 mu mol dm(-3) copper(II) was 1.47 % and for 1 mu mol dm(-3) copper(II), it was 3.40 %. The detection limit, calculated as 3 s/m (where s is a standard deviation of nine measurement of a reagent blank and m is the slope of the calibration curve), was 0.32 mu mol dm(-3), which corresponds to 2.44 ng of copper(II) (the loop volume was 0.12 cm(3)). The method enables 60 analyses per hour and it was successfully applied for the determination of copper in drinking water samples.
AB  - Cilj ovog rada bio je razvoj gasno-difuzione protočno injekcione metode sa amperometrijskom detekcijom za indirektno određivanje bakra na srebrnoj elektrodi. Protočni sistem je opremljen sa dva injekciona ventila i gasno-difuzionom jedinicom. U prvom koraku snima se signal rastvora cijanida, a u drugom snima se signal pri istovremenom ubrizgavanju rastvora cijanida i rastvora bakra. Smetnje od Cd(II), Co(II), Ag(I), Ni(II), Fe(III), Hg(II) i Zn(II) su ispitane i uspešno uklonjene. Kalibraciona kriva je linearna u opsegu 1-90 μmol dm-3 bakra, koeficijent korelacije je 0,993, a jednačina prave I = (0,0455±0,0015)c + (0,4611±0,0671), gde je I razlika visine signala u μA, a c je koncentracija u μmol dm-3. Relativna standardna devijacija za šest uzastopnih ubrizgavanja rastvora bakra koncentracije 30 μmol dm-3 je 1,47 %, a za 1 μmol dm-3 rastvor Cu(II) je 3,40 %. Limit detekcije, izračunat kao 3s/m (gde je s standardna devijacija devet merenja slepe probe i m je nagib kalibracione prave), je 0,32 μmol dm-3, što odgovara 2,44 ng Cu(II) (zapremina petlje za uzorak je 0,12 cm3). Metoda omogućava 60 analiza po jednom satu i uspešno je primenjena za određivanje bakra u pijaćoj vodi.
PB  - Serbian Chemical Soc, Belgrade
T2  - Journal of the Serbian Chemical Society
T1  - Development of a flow injection method with amperometric detection for the indirect determination of copper in drinking water samples
T1  - Razvoj protočne injekcione metode za indirektno određivanje bakra sa amperometrijskom detekcijom u pijaćoj vodi
VL  - 77
IS  - 11
SP  - 1641
EP  - 1647
DO  - 10.2298/JSC120616090L
ER  - 
@article{
author = "Lolić, Aleksandar and Tripkovic, Tatjana and Baošić, Rada and Nikolić-Mandić, Snežana D. and Stanimirović, Bojana",
year = "2012",
abstract = "A gas-diffusion flow injection method with amperometric detection for the indirect determination of copper on a silver electrode was developed. The flow through system was equipped with two injection valves and a gas-diffusion unit. In the first step, a signal of a cyanide solution was recorded. In the subsequent step, the signal of cyanide in the presence of copper was measured. Interferences (Cd(II), Co(II), Ag(I), Ni(II), Fe(III), Hg(II) and Zn(II)) were investigated and successfully removed. The calibration graph was linear in the range 1-90 mu mol dm(-3) of copper with a correlation coefficient of 0.993. The regression equation is I = (0.0455 +/- 0.0015)c + (0.4611 +/- 0.0671), where I is the relative signal decrease in mu A and c is concentration in mu mol dm(-3). Relative standard deviation for six consecutive injections of 30 mu mol dm(-3) copper(II) was 1.47 % and for 1 mu mol dm(-3) copper(II), it was 3.40 %. The detection limit, calculated as 3 s/m (where s is a standard deviation of nine measurement of a reagent blank and m is the slope of the calibration curve), was 0.32 mu mol dm(-3), which corresponds to 2.44 ng of copper(II) (the loop volume was 0.12 cm(3)). The method enables 60 analyses per hour and it was successfully applied for the determination of copper in drinking water samples., Cilj ovog rada bio je razvoj gasno-difuzione protočno injekcione metode sa amperometrijskom detekcijom za indirektno određivanje bakra na srebrnoj elektrodi. Protočni sistem je opremljen sa dva injekciona ventila i gasno-difuzionom jedinicom. U prvom koraku snima se signal rastvora cijanida, a u drugom snima se signal pri istovremenom ubrizgavanju rastvora cijanida i rastvora bakra. Smetnje od Cd(II), Co(II), Ag(I), Ni(II), Fe(III), Hg(II) i Zn(II) su ispitane i uspešno uklonjene. Kalibraciona kriva je linearna u opsegu 1-90 μmol dm-3 bakra, koeficijent korelacije je 0,993, a jednačina prave I = (0,0455±0,0015)c + (0,4611±0,0671), gde je I razlika visine signala u μA, a c je koncentracija u μmol dm-3. Relativna standardna devijacija za šest uzastopnih ubrizgavanja rastvora bakra koncentracije 30 μmol dm-3 je 1,47 %, a za 1 μmol dm-3 rastvor Cu(II) je 3,40 %. Limit detekcije, izračunat kao 3s/m (gde je s standardna devijacija devet merenja slepe probe i m je nagib kalibracione prave), je 0,32 μmol dm-3, što odgovara 2,44 ng Cu(II) (zapremina petlje za uzorak je 0,12 cm3). Metoda omogućava 60 analiza po jednom satu i uspešno je primenjena za određivanje bakra u pijaćoj vodi.",
publisher = "Serbian Chemical Soc, Belgrade",
journal = "Journal of the Serbian Chemical Society",
title = "Development of a flow injection method with amperometric detection for the indirect determination of copper in drinking water samples, Razvoj protočne injekcione metode za indirektno određivanje bakra sa amperometrijskom detekcijom u pijaćoj vodi",
volume = "77",
number = "11",
pages = "1641-1647",
doi = "10.2298/JSC120616090L"
}
Lolić, A., Tripkovic, T., Baošić, R., Nikolić-Mandić, S. D.,& Stanimirović, B.. (2012). Development of a flow injection method with amperometric detection for the indirect determination of copper in drinking water samples. in Journal of the Serbian Chemical Society
Serbian Chemical Soc, Belgrade., 77(11), 1641-1647.
https://doi.org/10.2298/JSC120616090L
Lolić A, Tripkovic T, Baošić R, Nikolić-Mandić SD, Stanimirović B. Development of a flow injection method with amperometric detection for the indirect determination of copper in drinking water samples. in Journal of the Serbian Chemical Society. 2012;77(11):1641-1647.
doi:10.2298/JSC120616090L .
Lolić, Aleksandar, Tripkovic, Tatjana, Baošić, Rada, Nikolić-Mandić, Snežana D., Stanimirović, Bojana, "Development of a flow injection method with amperometric detection for the indirect determination of copper in drinking water samples" in Journal of the Serbian Chemical Society, 77, no. 11 (2012):1641-1647,
https://doi.org/10.2298/JSC120616090L . .
1
2
2
1

RP-TLC Quantitative Retention-Property Relationships Studies of Some Schiff Base Ligands and Their Complexes

Baošić, Rada; Radojevic, Ana; Tripkovic, Tatjana; Aburas, Najat M.; Tešić, Živoslav Lj.

(Springer Heidelberg, Heidelberg, 2010)

TY  - JOUR
AU  - Baošić, Rada
AU  - Radojevic, Ana
AU  - Tripkovic, Tatjana
AU  - Aburas, Najat M.
AU  - Tešić, Živoslav Lj.
PY  - 2010
UR  - https://cherry.chem.bg.ac.rs/handle/123456789/1061
AB  - Mathematical models which define the effects of molecular properties on the retention and lipophilicity and prediction lipophilicity of some Schiff base ligands, and complexes with copper(II) and nickel(II) were developed. Following molecular descriptors were calculated: molecular volume, surface area, energy of the highest occupied/lowest unoccupied molecular orbital, dipole moment, refractivity, polarizability, hydrophilic-lipophilic balance, and lipophilicity parameters, which are correlated with chromatographically determinated lipophilicity parameters. A multiple linear regression procedure was used to derive the models. High agreement between experimental and predicted values obtained in this validation procedure indicates the good quality of the derived models.
PB  - Springer Heidelberg, Heidelberg
T2  - Chromatographia
T1  - RP-TLC Quantitative Retention-Property Relationships Studies of Some Schiff Base Ligands and Their Complexes
VL  - 72
IS  - 5-6
SP  - 545
EP  - 549
DO  - 10.1365/s10337-010-1664-0
ER  - 
@article{
author = "Baošić, Rada and Radojevic, Ana and Tripkovic, Tatjana and Aburas, Najat M. and Tešić, Živoslav Lj.",
year = "2010",
abstract = "Mathematical models which define the effects of molecular properties on the retention and lipophilicity and prediction lipophilicity of some Schiff base ligands, and complexes with copper(II) and nickel(II) were developed. Following molecular descriptors were calculated: molecular volume, surface area, energy of the highest occupied/lowest unoccupied molecular orbital, dipole moment, refractivity, polarizability, hydrophilic-lipophilic balance, and lipophilicity parameters, which are correlated with chromatographically determinated lipophilicity parameters. A multiple linear regression procedure was used to derive the models. High agreement between experimental and predicted values obtained in this validation procedure indicates the good quality of the derived models.",
publisher = "Springer Heidelberg, Heidelberg",
journal = "Chromatographia",
title = "RP-TLC Quantitative Retention-Property Relationships Studies of Some Schiff Base Ligands and Their Complexes",
volume = "72",
number = "5-6",
pages = "545-549",
doi = "10.1365/s10337-010-1664-0"
}
Baošić, R., Radojevic, A., Tripkovic, T., Aburas, N. M.,& Tešić, Ž. Lj.. (2010). RP-TLC Quantitative Retention-Property Relationships Studies of Some Schiff Base Ligands and Their Complexes. in Chromatographia
Springer Heidelberg, Heidelberg., 72(5-6), 545-549.
https://doi.org/10.1365/s10337-010-1664-0
Baošić R, Radojevic A, Tripkovic T, Aburas NM, Tešić ŽL. RP-TLC Quantitative Retention-Property Relationships Studies of Some Schiff Base Ligands and Their Complexes. in Chromatographia. 2010;72(5-6):545-549.
doi:10.1365/s10337-010-1664-0 .
Baošić, Rada, Radojevic, Ana, Tripkovic, Tatjana, Aburas, Najat M., Tešić, Živoslav Lj., "RP-TLC Quantitative Retention-Property Relationships Studies of Some Schiff Base Ligands and Their Complexes" in Chromatographia, 72, no. 5-6 (2010):545-549,
https://doi.org/10.1365/s10337-010-1664-0 . .
4
4
5
2