Jevtić, Sonja

Link to this page

Authority KeyName Variants
30bcc559-2c95-425a-95ed-a61575a3a2d1
  • Jevtić, Sonja (6)
Projects

Author's Bibliography

Hydrometallurgical Process for Selective Metals Recovery from Waste-Printed Circuit Boards

Kamberović, Željko; Ranitović, Milisav; Korać, Marija; Anđić, Zoran; Gajić, Nataša; Đokić, Jovana; Jevtić, Sonja

(Mdpi, Basel, 2018)

TY  - JOUR
AU  - Kamberović, Željko
AU  - Ranitović, Milisav
AU  - Korać, Marija
AU  - Anđić, Zoran
AU  - Gajić, Nataša
AU  - Đokić, Jovana
AU  - Jevtić, Sonja
PY  - 2018
UR  - https://cherry.chem.bg.ac.rs/handle/123456789/2164
AB  - This paper presents an experimentally-proved hydrometallurgical process for selective metals recovery from the waste-printed circuit boards (WPCBs) using a combination of conventional and time-saving methods: leaching, cementation, precipitation, reduction and electrowinning. According to the results obtained in the laboratory tests, 92.4% Cu, 98.5% Pb, 96.8% Ag and over 99% Au could be selectively leached and recovered using mineral acids: sulfuric, nitric and aqua regia. Problematic tin recovery was addressed with comprehensive theoretical and experimental work, so 55.4% of Sn could be recovered through the novel physical method, which consists of two-step phase separation. Based on the results, an integral hydrometallurgical route for selective base and precious metals recovery though consecutive steps, (i) Cu, (ii) Sn, (iii) Pb and Ag, and (iv) Au, was developed. The route was tested at scaled-up laboratory level, confirming feasibility of the process and efficiencies of metals recovery. According to the obtained results, the proposed hydrometallurgical route represents an innovative and promising method for selective metals recovery from WPCBs, particularly applicable in small scale hydrometallurgical environments, focused on medium and high grade WPCBs recycling.
PB  - Mdpi, Basel
T2  - METALS
T1  - Hydrometallurgical Process for Selective Metals Recovery from Waste-Printed Circuit Boards
VL  - 8
IS  - 6
DO  - 10.3390/met8060441
ER  - 
@article{
author = "Kamberović, Željko and Ranitović, Milisav and Korać, Marija and Anđić, Zoran and Gajić, Nataša and Đokić, Jovana and Jevtić, Sonja",
year = "2018",
abstract = "This paper presents an experimentally-proved hydrometallurgical process for selective metals recovery from the waste-printed circuit boards (WPCBs) using a combination of conventional and time-saving methods: leaching, cementation, precipitation, reduction and electrowinning. According to the results obtained in the laboratory tests, 92.4% Cu, 98.5% Pb, 96.8% Ag and over 99% Au could be selectively leached and recovered using mineral acids: sulfuric, nitric and aqua regia. Problematic tin recovery was addressed with comprehensive theoretical and experimental work, so 55.4% of Sn could be recovered through the novel physical method, which consists of two-step phase separation. Based on the results, an integral hydrometallurgical route for selective base and precious metals recovery though consecutive steps, (i) Cu, (ii) Sn, (iii) Pb and Ag, and (iv) Au, was developed. The route was tested at scaled-up laboratory level, confirming feasibility of the process and efficiencies of metals recovery. According to the obtained results, the proposed hydrometallurgical route represents an innovative and promising method for selective metals recovery from WPCBs, particularly applicable in small scale hydrometallurgical environments, focused on medium and high grade WPCBs recycling.",
publisher = "Mdpi, Basel",
journal = "METALS",
title = "Hydrometallurgical Process for Selective Metals Recovery from Waste-Printed Circuit Boards",
volume = "8",
number = "6",
doi = "10.3390/met8060441"
}
Kamberović, Ž., Ranitović, M., Korać, M., Anđić, Z., Gajić, N., Đokić, J.,& Jevtić, S.. (2018). Hydrometallurgical Process for Selective Metals Recovery from Waste-Printed Circuit Boards. in METALS
Mdpi, Basel., 8(6).
https://doi.org/10.3390/met8060441
Kamberović Ž, Ranitović M, Korać M, Anđić Z, Gajić N, Đokić J, Jevtić S. Hydrometallurgical Process for Selective Metals Recovery from Waste-Printed Circuit Boards. in METALS. 2018;8(6).
doi:10.3390/met8060441 .
Kamberović, Željko, Ranitović, Milisav, Korać, Marija, Anđić, Zoran, Gajić, Nataša, Đokić, Jovana, Jevtić, Sonja, "Hydrometallurgical Process for Selective Metals Recovery from Waste-Printed Circuit Boards" in METALS, 8, no. 6 (2018),
https://doi.org/10.3390/met8060441 . .
26
9
27
22

Boron-doped diamond electrode - A prestigious unmodified carbon electrode for simple and fast determination of bentazone in river water samples

Jevtić, Sonja; Stefanović, Anđela; Stanković, Dalibor; Pergal, Marija V.; Ivanović, Aleksandra T.; Jokić, Anja; Petković, Branka B.

(Elsevier Science Sa, Lausanne, 2018)

TY  - JOUR
AU  - Jevtić, Sonja
AU  - Stefanović, Anđela
AU  - Stanković, Dalibor
AU  - Pergal, Marija V.
AU  - Ivanović, Aleksandra T.
AU  - Jokić, Anja
AU  - Petković, Branka B.
PY  - 2018
UR  - https://cherry.chem.bg.ac.rs/handle/123456789/2081
AB  - Bentazone (BZ) is selective contact-past herbicide with suspected reproductive toxicity potential for human due to possible contamination of ground and surface waters. This work presents simple, rapid, sensitive and accurate determination of bentazone at unmodified boron-doped diamond electrode, using differential pulse voltammetry in Britton-Robinson buffer (pH 4, oxidation peak at 1.0 V). Under optimized DPV conditions linear calibration curve was obtained for range of 2 to 100 mu M, with a detection limit of 0.5 mu M. The effect of possible interfering agents is negligible, confirming good selectivity of the method. The method was successfully applied to determination of bentazone in spiked river water samples. This electrochemical determination of bentazone represents a favorable alternative to other used time-consuming and expensive analytical techniques and procedures.
PB  - Elsevier Science Sa, Lausanne
T2  - Diamond and Related Materials
T1  - Boron-doped diamond electrode - A prestigious unmodified carbon electrode for simple and fast determination of bentazone in river water samples
VL  - 81
SP  - 133
EP  - 137
DO  - 10.1016/j.diamond.2017.12.009
ER  - 
@article{
author = "Jevtić, Sonja and Stefanović, Anđela and Stanković, Dalibor and Pergal, Marija V. and Ivanović, Aleksandra T. and Jokić, Anja and Petković, Branka B.",
year = "2018",
abstract = "Bentazone (BZ) is selective contact-past herbicide with suspected reproductive toxicity potential for human due to possible contamination of ground and surface waters. This work presents simple, rapid, sensitive and accurate determination of bentazone at unmodified boron-doped diamond electrode, using differential pulse voltammetry in Britton-Robinson buffer (pH 4, oxidation peak at 1.0 V). Under optimized DPV conditions linear calibration curve was obtained for range of 2 to 100 mu M, with a detection limit of 0.5 mu M. The effect of possible interfering agents is negligible, confirming good selectivity of the method. The method was successfully applied to determination of bentazone in spiked river water samples. This electrochemical determination of bentazone represents a favorable alternative to other used time-consuming and expensive analytical techniques and procedures.",
publisher = "Elsevier Science Sa, Lausanne",
journal = "Diamond and Related Materials",
title = "Boron-doped diamond electrode - A prestigious unmodified carbon electrode for simple and fast determination of bentazone in river water samples",
volume = "81",
pages = "133-137",
doi = "10.1016/j.diamond.2017.12.009"
}
Jevtić, S., Stefanović, A., Stanković, D., Pergal, M. V., Ivanović, A. T., Jokić, A.,& Petković, B. B.. (2018). Boron-doped diamond electrode - A prestigious unmodified carbon electrode for simple and fast determination of bentazone in river water samples. in Diamond and Related Materials
Elsevier Science Sa, Lausanne., 81, 133-137.
https://doi.org/10.1016/j.diamond.2017.12.009
Jevtić S, Stefanović A, Stanković D, Pergal MV, Ivanović AT, Jokić A, Petković BB. Boron-doped diamond electrode - A prestigious unmodified carbon electrode for simple and fast determination of bentazone in river water samples. in Diamond and Related Materials. 2018;81:133-137.
doi:10.1016/j.diamond.2017.12.009 .
Jevtić, Sonja, Stefanović, Anđela, Stanković, Dalibor, Pergal, Marija V., Ivanović, Aleksandra T., Jokić, Anja, Petković, Branka B., "Boron-doped diamond electrode - A prestigious unmodified carbon electrode for simple and fast determination of bentazone in river water samples" in Diamond and Related Materials, 81 (2018):133-137,
https://doi.org/10.1016/j.diamond.2017.12.009 . .
37
25
38
33

Herbicide Clomazone Detection Using Electroanalytical Approach Using Boron Doped Diamond Electrode

Đurđić, Slađana Z.; Vukojević, Vesna; Jevtić, Sonja; Pergal, Marija V.; Petković, Branka B.; Stanković, Dalibor

(Esg, Belgrade, 2018)

TY  - JOUR
AU  - Đurđić, Slađana Z.
AU  - Vukojević, Vesna
AU  - Jevtić, Sonja
AU  - Pergal, Marija V.
AU  - Petković, Branka B.
AU  - Stanković, Dalibor
PY  - 2018
UR  - https://cherry.chem.bg.ac.rs/handle/123456789/2124
AB  - In this work, for the first time we proposed electrochemical behavior and development of an analytical procedure for quantification of pesticide clomazone. Electrochemical behavior of clomazone's at boron-doped diamond electrode is characterized with irreversible oxidation at potential of around 1.6 V, in Britton-Robinson buffer solution at pH 2. It was found that potential of this oxidation was not pH dependent excluding presence of proton in the electrochemical reaction. Square wave voltammetry method was the most appropriate for clomazone quantification and proposed procedure was successfully applied for determination of clomazone in river water samples. Obtained parameters, detection limit of 0.21 mu M and working linear range from 1 to 100 mu M and satisfied selectivity can indicate that presented results open new field in research of this group of pesticides and offer possible replacement to the sophisticated and expensive chromatographic methods.
PB  - Esg, Belgrade
T2  - International Journal of Electrochemical Science
T1  - Herbicide Clomazone Detection Using Electroanalytical Approach Using Boron Doped Diamond Electrode
VL  - 13
IS  - 3
SP  - 2791
EP  - 2799
DO  - 10.20964/2018.03.39
ER  - 
@article{
author = "Đurđić, Slađana Z. and Vukojević, Vesna and Jevtić, Sonja and Pergal, Marija V. and Petković, Branka B. and Stanković, Dalibor",
year = "2018",
abstract = "In this work, for the first time we proposed electrochemical behavior and development of an analytical procedure for quantification of pesticide clomazone. Electrochemical behavior of clomazone's at boron-doped diamond electrode is characterized with irreversible oxidation at potential of around 1.6 V, in Britton-Robinson buffer solution at pH 2. It was found that potential of this oxidation was not pH dependent excluding presence of proton in the electrochemical reaction. Square wave voltammetry method was the most appropriate for clomazone quantification and proposed procedure was successfully applied for determination of clomazone in river water samples. Obtained parameters, detection limit of 0.21 mu M and working linear range from 1 to 100 mu M and satisfied selectivity can indicate that presented results open new field in research of this group of pesticides and offer possible replacement to the sophisticated and expensive chromatographic methods.",
publisher = "Esg, Belgrade",
journal = "International Journal of Electrochemical Science",
title = "Herbicide Clomazone Detection Using Electroanalytical Approach Using Boron Doped Diamond Electrode",
volume = "13",
number = "3",
pages = "2791-2799",
doi = "10.20964/2018.03.39"
}
Đurđić, S. Z., Vukojević, V., Jevtić, S., Pergal, M. V., Petković, B. B.,& Stanković, D.. (2018). Herbicide Clomazone Detection Using Electroanalytical Approach Using Boron Doped Diamond Electrode. in International Journal of Electrochemical Science
Esg, Belgrade., 13(3), 2791-2799.
https://doi.org/10.20964/2018.03.39
Đurđić SZ, Vukojević V, Jevtić S, Pergal MV, Petković BB, Stanković D. Herbicide Clomazone Detection Using Electroanalytical Approach Using Boron Doped Diamond Electrode. in International Journal of Electrochemical Science. 2018;13(3):2791-2799.
doi:10.20964/2018.03.39 .
Đurđić, Slađana Z., Vukojević, Vesna, Jevtić, Sonja, Pergal, Marija V., Petković, Branka B., Stanković, Dalibor, "Herbicide Clomazone Detection Using Electroanalytical Approach Using Boron Doped Diamond Electrode" in International Journal of Electrochemical Science, 13, no. 3 (2018):2791-2799,
https://doi.org/10.20964/2018.03.39 . .
9
5
12
6

First electrochemistry of herbicide pethoxamid and its quantification using electroanalytical approach from mixed commercial product

Jevtić, Sonja; Vukojević, Vesna; Đurđić, Slađana Z.; Pergal, Marija V.; Manojlović, Dragan D.; Petković, Branka B.; Stanković, Dalibor

(Pergamon-Elsevier Science Ltd, Oxford, 2018)

TY  - JOUR
AU  - Jevtić, Sonja
AU  - Vukojević, Vesna
AU  - Đurđić, Slađana Z.
AU  - Pergal, Marija V.
AU  - Manojlović, Dragan D.
AU  - Petković, Branka B.
AU  - Stanković, Dalibor
PY  - 2018
UR  - https://cherry.chem.bg.ac.rs/handle/123456789/2144
AB  - This work present a new approach for the detection of relatively new herbicide pethoxamid (POA), a first electrochemical behavior and determination based on its oxidation on boron-doped diamond electrode in Britton-Robinson buffer solution at pH 4. Square wave voltammetric technique was used for quantification of POA at anodic potential of 1.35 V vs reference Ag/AgCl electrode. The proposed electroanalytical method is operational in the linear working range from 3 to 100 mu M of POA with a limit of detection of 1.37 mu M. The developed analytical procedure was successfully tested for determination of this herbicide in standard/spiked river water samples and commercial herbicide Successor T SE/spiked river water samples, offering a simple, fast and inexpensive alternative way of pesticide determining to chromatographic methods employed for this purpose. (C) 2018 Elsevier Ltd. All rights reserved.
PB  - Pergamon-Elsevier Science Ltd, Oxford
T2  - Electrochimica Acta
T1  - First electrochemistry of herbicide pethoxamid and its quantification using electroanalytical approach from mixed commercial product
VL  - 277
SP  - 136
EP  - 142
DO  - 10.1016/j.electacta.2018.05.004
ER  - 
@article{
author = "Jevtić, Sonja and Vukojević, Vesna and Đurđić, Slađana Z. and Pergal, Marija V. and Manojlović, Dragan D. and Petković, Branka B. and Stanković, Dalibor",
year = "2018",
abstract = "This work present a new approach for the detection of relatively new herbicide pethoxamid (POA), a first electrochemical behavior and determination based on its oxidation on boron-doped diamond electrode in Britton-Robinson buffer solution at pH 4. Square wave voltammetric technique was used for quantification of POA at anodic potential of 1.35 V vs reference Ag/AgCl electrode. The proposed electroanalytical method is operational in the linear working range from 3 to 100 mu M of POA with a limit of detection of 1.37 mu M. The developed analytical procedure was successfully tested for determination of this herbicide in standard/spiked river water samples and commercial herbicide Successor T SE/spiked river water samples, offering a simple, fast and inexpensive alternative way of pesticide determining to chromatographic methods employed for this purpose. (C) 2018 Elsevier Ltd. All rights reserved.",
publisher = "Pergamon-Elsevier Science Ltd, Oxford",
journal = "Electrochimica Acta",
title = "First electrochemistry of herbicide pethoxamid and its quantification using electroanalytical approach from mixed commercial product",
volume = "277",
pages = "136-142",
doi = "10.1016/j.electacta.2018.05.004"
}
Jevtić, S., Vukojević, V., Đurđić, S. Z., Pergal, M. V., Manojlović, D. D., Petković, B. B.,& Stanković, D.. (2018). First electrochemistry of herbicide pethoxamid and its quantification using electroanalytical approach from mixed commercial product. in Electrochimica Acta
Pergamon-Elsevier Science Ltd, Oxford., 277, 136-142.
https://doi.org/10.1016/j.electacta.2018.05.004
Jevtić S, Vukojević V, Đurđić SZ, Pergal MV, Manojlović DD, Petković BB, Stanković D. First electrochemistry of herbicide pethoxamid and its quantification using electroanalytical approach from mixed commercial product. in Electrochimica Acta. 2018;277:136-142.
doi:10.1016/j.electacta.2018.05.004 .
Jevtić, Sonja, Vukojević, Vesna, Đurđić, Slađana Z., Pergal, Marija V., Manojlović, Dragan D., Petković, Branka B., Stanković, Dalibor, "First electrochemistry of herbicide pethoxamid and its quantification using electroanalytical approach from mixed commercial product" in Electrochimica Acta, 277 (2018):136-142,
https://doi.org/10.1016/j.electacta.2018.05.004 . .
16
8
17
13

Boron-doped diamond electrode - A prestigious unmodified carbon electrode for simple and fast determination of bentazone in river water samples

Jevtić, Sonja; Stefanović, Anđela; Stanković, Dalibor; Pergal, Marija V.; Ivanović, Aleksandra T.; Jokić, Anja; Petković, Branka B.

(Elsevier Science Sa, Lausanne, 2018)

TY  - JOUR
AU  - Jevtić, Sonja
AU  - Stefanović, Anđela
AU  - Stanković, Dalibor
AU  - Pergal, Marija V.
AU  - Ivanović, Aleksandra T.
AU  - Jokić, Anja
AU  - Petković, Branka B.
PY  - 2018
UR  - https://cherry.chem.bg.ac.rs/handle/123456789/3177
AB  - Bentazone (BZ) is selective contact-past herbicide with suspected reproductive toxicity potential for human due to possible contamination of ground and surface waters. This work presents simple, rapid, sensitive and accurate determination of bentazone at unmodified boron-doped diamond electrode, using differential pulse voltammetry in Britton-Robinson buffer (pH 4, oxidation peak at 1.0 V). Under optimized DPV conditions linear calibration curve was obtained for range of 2 to 100 mu M, with a detection limit of 0.5 mu M. The effect of possible interfering agents is negligible, confirming good selectivity of the method. The method was successfully applied to determination of bentazone in spiked river water samples. This electrochemical determination of bentazone represents a favorable alternative to other used time-consuming and expensive analytical techniques and procedures.
PB  - Elsevier Science Sa, Lausanne
T2  - Diamond and Related Materials
T1  - Boron-doped diamond electrode - A prestigious unmodified carbon electrode for simple and fast determination of bentazone in river water samples
VL  - 81
SP  - 133
EP  - 137
DO  - 10.1016/j.diamond.2017.12.009
ER  - 
@article{
author = "Jevtić, Sonja and Stefanović, Anđela and Stanković, Dalibor and Pergal, Marija V. and Ivanović, Aleksandra T. and Jokić, Anja and Petković, Branka B.",
year = "2018",
abstract = "Bentazone (BZ) is selective contact-past herbicide with suspected reproductive toxicity potential for human due to possible contamination of ground and surface waters. This work presents simple, rapid, sensitive and accurate determination of bentazone at unmodified boron-doped diamond electrode, using differential pulse voltammetry in Britton-Robinson buffer (pH 4, oxidation peak at 1.0 V). Under optimized DPV conditions linear calibration curve was obtained for range of 2 to 100 mu M, with a detection limit of 0.5 mu M. The effect of possible interfering agents is negligible, confirming good selectivity of the method. The method was successfully applied to determination of bentazone in spiked river water samples. This electrochemical determination of bentazone represents a favorable alternative to other used time-consuming and expensive analytical techniques and procedures.",
publisher = "Elsevier Science Sa, Lausanne",
journal = "Diamond and Related Materials",
title = "Boron-doped diamond electrode - A prestigious unmodified carbon electrode for simple and fast determination of bentazone in river water samples",
volume = "81",
pages = "133-137",
doi = "10.1016/j.diamond.2017.12.009"
}
Jevtić, S., Stefanović, A., Stanković, D., Pergal, M. V., Ivanović, A. T., Jokić, A.,& Petković, B. B.. (2018). Boron-doped diamond electrode - A prestigious unmodified carbon electrode for simple and fast determination of bentazone in river water samples. in Diamond and Related Materials
Elsevier Science Sa, Lausanne., 81, 133-137.
https://doi.org/10.1016/j.diamond.2017.12.009
Jevtić S, Stefanović A, Stanković D, Pergal MV, Ivanović AT, Jokić A, Petković BB. Boron-doped diamond electrode - A prestigious unmodified carbon electrode for simple and fast determination of bentazone in river water samples. in Diamond and Related Materials. 2018;81:133-137.
doi:10.1016/j.diamond.2017.12.009 .
Jevtić, Sonja, Stefanović, Anđela, Stanković, Dalibor, Pergal, Marija V., Ivanović, Aleksandra T., Jokić, Anja, Petković, Branka B., "Boron-doped diamond electrode - A prestigious unmodified carbon electrode for simple and fast determination of bentazone in river water samples" in Diamond and Related Materials, 81 (2018):133-137,
https://doi.org/10.1016/j.diamond.2017.12.009 . .
37
25
36
33

Supplementary material for the article: Jevtić, S.; Stefanović, A.; Stanković, D. M.; Pergal, M. V.; Ivanović, A. T.; Jokić, A.; Petković, B. B. Boron-Doped Diamond Electrode — A Prestigious Unmodified Carbon Electrode for Simple and Fast Determination of Bentazone in River Water Samples. Diamond and Related Materials 2018, 81, 133–137. https://doi.org/10.1016/j.diamond.2017.12.009

Jevtić, Sonja; Stefanović, Anđela; Stanković, Dalibor; Pergal, Marija V.; Ivanović, Aleksandra T.; Jokić, Anja; Petković, Branka B.

(Elsevier Science Sa, Lausanne, 2018)

TY  - DATA
AU  - Jevtić, Sonja
AU  - Stefanović, Anđela
AU  - Stanković, Dalibor
AU  - Pergal, Marija V.
AU  - Ivanović, Aleksandra T.
AU  - Jokić, Anja
AU  - Petković, Branka B.
PY  - 2018
UR  - https://cherry.chem.bg.ac.rs/handle/123456789/3178
PB  - Elsevier Science Sa, Lausanne
T2  - Diamond and Related Materials
T1  - Supplementary material for the article: Jevtić, S.; Stefanović, A.; Stanković, D. M.; Pergal, M. V.; Ivanović, A. T.; Jokić, A.;  Petković, B. B. Boron-Doped Diamond Electrode — A Prestigious Unmodified Carbon  Electrode for Simple and Fast Determination of Bentazone in River Water Samples. Diamond  and Related Materials 2018, 81, 133–137. https://doi.org/10.1016/j.diamond.2017.12.009
UR  - https://hdl.handle.net/21.15107/rcub_cherry_3178
ER  - 
@misc{
author = "Jevtić, Sonja and Stefanović, Anđela and Stanković, Dalibor and Pergal, Marija V. and Ivanović, Aleksandra T. and Jokić, Anja and Petković, Branka B.",
year = "2018",
publisher = "Elsevier Science Sa, Lausanne",
journal = "Diamond and Related Materials",
title = "Supplementary material for the article: Jevtić, S.; Stefanović, A.; Stanković, D. M.; Pergal, M. V.; Ivanović, A. T.; Jokić, A.;  Petković, B. B. Boron-Doped Diamond Electrode — A Prestigious Unmodified Carbon  Electrode for Simple and Fast Determination of Bentazone in River Water Samples. Diamond  and Related Materials 2018, 81, 133–137. https://doi.org/10.1016/j.diamond.2017.12.009",
url = "https://hdl.handle.net/21.15107/rcub_cherry_3178"
}
Jevtić, S., Stefanović, A., Stanković, D., Pergal, M. V., Ivanović, A. T., Jokić, A.,& Petković, B. B.. (2018). Supplementary material for the article: Jevtić, S.; Stefanović, A.; Stanković, D. M.; Pergal, M. V.; Ivanović, A. T.; Jokić, A.;  Petković, B. B. Boron-Doped Diamond Electrode — A Prestigious Unmodified Carbon  Electrode for Simple and Fast Determination of Bentazone in River Water Samples. Diamond  and Related Materials 2018, 81, 133–137. https://doi.org/10.1016/j.diamond.2017.12.009. in Diamond and Related Materials
Elsevier Science Sa, Lausanne..
https://hdl.handle.net/21.15107/rcub_cherry_3178
Jevtić S, Stefanović A, Stanković D, Pergal MV, Ivanović AT, Jokić A, Petković BB. Supplementary material for the article: Jevtić, S.; Stefanović, A.; Stanković, D. M.; Pergal, M. V.; Ivanović, A. T.; Jokić, A.;  Petković, B. B. Boron-Doped Diamond Electrode — A Prestigious Unmodified Carbon  Electrode for Simple and Fast Determination of Bentazone in River Water Samples. Diamond  and Related Materials 2018, 81, 133–137. https://doi.org/10.1016/j.diamond.2017.12.009. in Diamond and Related Materials. 2018;.
https://hdl.handle.net/21.15107/rcub_cherry_3178 .
Jevtić, Sonja, Stefanović, Anđela, Stanković, Dalibor, Pergal, Marija V., Ivanović, Aleksandra T., Jokić, Anja, Petković, Branka B., "Supplementary material for the article: Jevtić, S.; Stefanović, A.; Stanković, D. M.; Pergal, M. V.; Ivanović, A. T.; Jokić, A.;  Petković, B. B. Boron-Doped Diamond Electrode — A Prestigious Unmodified Carbon  Electrode for Simple and Fast Determination of Bentazone in River Water Samples. Diamond  and Related Materials 2018, 81, 133–137. https://doi.org/10.1016/j.diamond.2017.12.009" in Diamond and Related Materials (2018),
https://hdl.handle.net/21.15107/rcub_cherry_3178 .