Beletić, Anđelo D.

Link to this page

Authority KeyName Variants
7e4cf3a6-9958-432d-8ce0-c5465cd4deb3
  • Beletić, Anđelo D. (1)
Projects

Author's Bibliography

Novel approach to the measurement of antithyroglobulin antibodies in human serum – application of the quartz crystal microbalance sensors

Vrhovac, Lidija; Šelemetjev, Sonja A.; Vatić, Saša; Mitrović, Aleksandar; Milošević, Jelica; Lolić, Aleksandar; Beletić, Anđelo D.; Polović, Natalija

(Elsevier, 2021)

TY  - JOUR
AU  - Vrhovac, Lidija
AU  - Šelemetjev, Sonja A.
AU  - Vatić, Saša
AU  - Mitrović, Aleksandar
AU  - Milošević, Jelica
AU  - Lolić, Aleksandar
AU  - Beletić, Anđelo D.
AU  - Polović, Natalija
PY  - 2021
UR  - https://cherry.chem.bg.ac.rs/handle/123456789/4295
AB  - Measurement of antithyroglobulin antibodies (TgAb) is an inevitable laboratory tool in the management of thyroid gland diseases. Currently available immunoassays still have limitations underlying the necessity of the introduction of fast, sensitive, and label-free technologies. Our aim was to develop a method for TgAb measurement in human serum based on the quartz crystal microbalance (QCM) technology. We immobilized thyroglobulin on the surface of Attana LNB Carboxyl sensor chip®, prepared standard curve covering the range of 1–50000 kIU/L, and established optimal measurement conditions. The validation included determination of the detection limit (LOD), functional sensitivity, linearity, precision, as well as the comparison with the results of the radioimmunoassay (RIA). The LOD and functional sensitivity were 4.2 kIU/L and 4.7 kIU/L, respectively. The method was linear in the range of 20–10000 kIU/L. The regression equation for comparison with RIA was CQCM = 1.0056 • CRIA – 24.2778, whereby no significant proportional or systematic difference was present. There was a good agreement with RIA in the classification of patients according to the clinical significance of the results. The developed method has advantages over currently available assays in terms of better LOQ, a higher upper limit of linearity, and precision. The characteristics of the developed method unambiguously show that the application of the QCM biosensors offers a highly reliable novel approach for the measurement of TgAb in human serum.
PB  - Elsevier
T2  - Talanta
T1  - Novel approach to the measurement of antithyroglobulin antibodies in human serum – application of the quartz crystal microbalance sensors
VL  - 223
SP  - 121588
DO  - 10.1016/j.talanta.2020.121588
ER  - 
@article{
author = "Vrhovac, Lidija and Šelemetjev, Sonja A. and Vatić, Saša and Mitrović, Aleksandar and Milošević, Jelica and Lolić, Aleksandar and Beletić, Anđelo D. and Polović, Natalija",
year = "2021",
abstract = "Measurement of antithyroglobulin antibodies (TgAb) is an inevitable laboratory tool in the management of thyroid gland diseases. Currently available immunoassays still have limitations underlying the necessity of the introduction of fast, sensitive, and label-free technologies. Our aim was to develop a method for TgAb measurement in human serum based on the quartz crystal microbalance (QCM) technology. We immobilized thyroglobulin on the surface of Attana LNB Carboxyl sensor chip®, prepared standard curve covering the range of 1–50000 kIU/L, and established optimal measurement conditions. The validation included determination of the detection limit (LOD), functional sensitivity, linearity, precision, as well as the comparison with the results of the radioimmunoassay (RIA). The LOD and functional sensitivity were 4.2 kIU/L and 4.7 kIU/L, respectively. The method was linear in the range of 20–10000 kIU/L. The regression equation for comparison with RIA was CQCM = 1.0056 • CRIA – 24.2778, whereby no significant proportional or systematic difference was present. There was a good agreement with RIA in the classification of patients according to the clinical significance of the results. The developed method has advantages over currently available assays in terms of better LOQ, a higher upper limit of linearity, and precision. The characteristics of the developed method unambiguously show that the application of the QCM biosensors offers a highly reliable novel approach for the measurement of TgAb in human serum.",
publisher = "Elsevier",
journal = "Talanta",
title = "Novel approach to the measurement of antithyroglobulin antibodies in human serum – application of the quartz crystal microbalance sensors",
volume = "223",
pages = "121588",
doi = "10.1016/j.talanta.2020.121588"
}
Vrhovac, L., Šelemetjev, S. A., Vatić, S., Mitrović, A., Milošević, J., Lolić, A., Beletić, A. D.,& Polović, N.. (2021). Novel approach to the measurement of antithyroglobulin antibodies in human serum – application of the quartz crystal microbalance sensors. in Talanta
Elsevier., 223, 121588.
https://doi.org/10.1016/j.talanta.2020.121588
Vrhovac L, Šelemetjev SA, Vatić S, Mitrović A, Milošević J, Lolić A, Beletić AD, Polović N. Novel approach to the measurement of antithyroglobulin antibodies in human serum – application of the quartz crystal microbalance sensors. in Talanta. 2021;223:121588.
doi:10.1016/j.talanta.2020.121588 .
Vrhovac, Lidija, Šelemetjev, Sonja A., Vatić, Saša, Mitrović, Aleksandar, Milošević, Jelica, Lolić, Aleksandar, Beletić, Anđelo D., Polović, Natalija, "Novel approach to the measurement of antithyroglobulin antibodies in human serum – application of the quartz crystal microbalance sensors" in Talanta, 223 (2021):121588,
https://doi.org/10.1016/j.talanta.2020.121588 . .
6
1
4
4