Knežević, Sara

Link to this page

Authority KeyName Variants
c7503a8a-22c0-42cf-90db-109a553579eb
  • Knežević, Sara (5)
Projects

Author's Bibliography

S-Adenosyl-L-Homocysteine Hydrolase Immobilized on Citric Acid-capped Gallium Oxyhydroxide on SWCNTs Modified Electrode for AdoHcy Impedimetric Sensing

Knežević, Sara; Ognjanović, Miloš; Gavrović-Jankulović, Marija; Đurašinović, Tatjana; Antić, Bratislav; Vranješ-Đurić, Sanja; Stanković, Dalibor

(Wiley, 2021)

TY  - JOUR
AU  - Knežević, Sara
AU  - Ognjanović, Miloš
AU  - Gavrović-Jankulović, Marija
AU  - Đurašinović, Tatjana
AU  - Antić, Bratislav
AU  - Vranješ-Đurić, Sanja
AU  - Stanković, Dalibor
PY  - 2021
UR  - https://cherry.chem.bg.ac.rs/handle/123456789/4720
AB  - S-Adenosyl-L-Homocysteine (AdoHcy) is a crucial pathological factor in homocysteine-associated disorders. We developed an impedimetric approach for single drop S-Adenosyl-L-Homocysteine detection, based on S-Adenosyl-L-Homocysteine hydrolase (SAH), produced in the prokaryotic expression system (E. coli) by recombinant DNA technology, immobilized on citrate acid-coated gallium oxyhydroxide dispersed over single-walled carbon nanotubes (CA/GaO(OH)@SWCNT). The proposed biosensor offers detection of AdoHcy, with a limit of detection (LOD) of 0.17 μM. with operating linear range from 1 to 44 μM. The remarkable stability of gallium oxyhydroxide crystal was further improved by citric acid coating and its optical, electrical and physical anisotropy was skipped using SWCNTs.
PB  - Wiley
T2  - Electroanalysis
T1  - S-Adenosyl-L-Homocysteine Hydrolase Immobilized on Citric Acid-capped Gallium Oxyhydroxide on SWCNTs Modified Electrode for AdoHcy Impedimetric Sensing
VL  - n/a
IS  - n/a
DO  - 10.1002/elan.202100362
ER  - 
@article{
author = "Knežević, Sara and Ognjanović, Miloš and Gavrović-Jankulović, Marija and Đurašinović, Tatjana and Antić, Bratislav and Vranješ-Đurić, Sanja and Stanković, Dalibor",
year = "2021",
abstract = "S-Adenosyl-L-Homocysteine (AdoHcy) is a crucial pathological factor in homocysteine-associated disorders. We developed an impedimetric approach for single drop S-Adenosyl-L-Homocysteine detection, based on S-Adenosyl-L-Homocysteine hydrolase (SAH), produced in the prokaryotic expression system (E. coli) by recombinant DNA technology, immobilized on citrate acid-coated gallium oxyhydroxide dispersed over single-walled carbon nanotubes (CA/GaO(OH)@SWCNT). The proposed biosensor offers detection of AdoHcy, with a limit of detection (LOD) of 0.17 μM. with operating linear range from 1 to 44 μM. The remarkable stability of gallium oxyhydroxide crystal was further improved by citric acid coating and its optical, electrical and physical anisotropy was skipped using SWCNTs.",
publisher = "Wiley",
journal = "Electroanalysis",
title = "S-Adenosyl-L-Homocysteine Hydrolase Immobilized on Citric Acid-capped Gallium Oxyhydroxide on SWCNTs Modified Electrode for AdoHcy Impedimetric Sensing",
volume = "n/a",
number = "n/a",
doi = "10.1002/elan.202100362"
}
Knežević, S., Ognjanović, M., Gavrović-Jankulović, M., Đurašinović, T., Antić, B., Vranješ-Đurić, S.,& Stanković, D.. (2021). S-Adenosyl-L-Homocysteine Hydrolase Immobilized on Citric Acid-capped Gallium Oxyhydroxide on SWCNTs Modified Electrode for AdoHcy Impedimetric Sensing. in Electroanalysis
Wiley., n/a(n/a).
https://doi.org/10.1002/elan.202100362
Knežević S, Ognjanović M, Gavrović-Jankulović M, Đurašinović T, Antić B, Vranješ-Đurić S, Stanković D. S-Adenosyl-L-Homocysteine Hydrolase Immobilized on Citric Acid-capped Gallium Oxyhydroxide on SWCNTs Modified Electrode for AdoHcy Impedimetric Sensing. in Electroanalysis. 2021;n/a(n/a).
doi:10.1002/elan.202100362 .
Knežević, Sara, Ognjanović, Miloš, Gavrović-Jankulović, Marija, Đurašinović, Tatjana, Antić, Bratislav, Vranješ-Đurić, Sanja, Stanković, Dalibor, "S-Adenosyl-L-Homocysteine Hydrolase Immobilized on Citric Acid-capped Gallium Oxyhydroxide on SWCNTs Modified Electrode for AdoHcy Impedimetric Sensing" in Electroanalysis, n/a, no. n/a (2021),
https://doi.org/10.1002/elan.202100362 . .
1

Uticaj veličine čestica bizmut oksida na elektrokatalitičke osobine materijala

Knežević, Sara

(2021)

TY  - THES
AU  - Knežević, Sara
PY  - 2021
UR  - https://cherry.chem.bg.ac.rs/handle/123456789/4524
AB  - Honokiol je neolignan prisutan u kori drveta magnolije. Poseduje raznovrsne farmakološke osobine od kojih su najznačajnije neuroprotektivni i anksiolitički efekat, antikancerogena aktivnost i antimikrobni efekat. Cilj ovog istraživanja je razvoj voltametrijskog neenzimskog senzora za detekciju i kvantifikaciju honokiola, kao i praćenje njegove koncentracije u lekovima i kozmetičkim preparatima. Morfologija materijala sintetisanih u ovoj studiji je okarakterisana pomoću HR-XRPD, SEM, ATR-FTIR i elektrohemijskim metodama. Bi2O3, poluprovodnik p tipa, je korišćen kao elektrodni materijal. Njegova poluprovodljivost i elektrokatalitičke osobine su rezultat defekata u strukturi kristalne rešetke koji se razlikuju na površini i u unutrašnjosti kristala bizmut oksida, te stoga zavise od veličine kristala. Ispitan je uticaj veličine čestica Bi2O3 na njegove elektrokatalitičke osobine i potvrđeno je da nanočestice Bi2O3 imaju bolje provodne/otporne i katalitičke osobine od mikročestica i da je optimalna modifikacija elektrode za detekciju honokiola dobijena pripremom Bi2O3@SWCNT kompozitnog materijala. Limit detekcije ovakavog sistema, pri optimizovanim uslovima, je 0,17 μM, a opseg linearnosti metode je od 0,1 μM do 50 μM. Ispitan je uticaj potencijalnih interferirajućih vrsta na detekciju honokiola, kao i praktična upotrebljivost senzora za analizu realnih uzoraka čime je utvrđeno da razvijen pristup pokazuje veliku tačnost, selektivnost i reproduktivnost. Zahvaljujući niskoj granici detekcije i širokom radnom opsegu, predložena senzorska platforma otvara mogućnosti za konstrukciju senzora za detekciju i praćenje koncentracije honokiola u farmaceutskoj industriji i istraživanjima u medicinskoj hemiji.
T1  - Uticaj veličine čestica bizmut oksida na elektrokatalitičke osobine materijala
SP  - 1
EP  - 39
ER  - 
@mastersthesis{
author = "Knežević, Sara",
year = "2021",
abstract = "Honokiol je neolignan prisutan u kori drveta magnolije. Poseduje raznovrsne farmakološke osobine od kojih su najznačajnije neuroprotektivni i anksiolitički efekat, antikancerogena aktivnost i antimikrobni efekat. Cilj ovog istraživanja je razvoj voltametrijskog neenzimskog senzora za detekciju i kvantifikaciju honokiola, kao i praćenje njegove koncentracije u lekovima i kozmetičkim preparatima. Morfologija materijala sintetisanih u ovoj studiji je okarakterisana pomoću HR-XRPD, SEM, ATR-FTIR i elektrohemijskim metodama. Bi2O3, poluprovodnik p tipa, je korišćen kao elektrodni materijal. Njegova poluprovodljivost i elektrokatalitičke osobine su rezultat defekata u strukturi kristalne rešetke koji se razlikuju na površini i u unutrašnjosti kristala bizmut oksida, te stoga zavise od veličine kristala. Ispitan je uticaj veličine čestica Bi2O3 na njegove elektrokatalitičke osobine i potvrđeno je da nanočestice Bi2O3 imaju bolje provodne/otporne i katalitičke osobine od mikročestica i da je optimalna modifikacija elektrode za detekciju honokiola dobijena pripremom Bi2O3@SWCNT kompozitnog materijala. Limit detekcije ovakavog sistema, pri optimizovanim uslovima, je 0,17 μM, a opseg linearnosti metode je od 0,1 μM do 50 μM. Ispitan je uticaj potencijalnih interferirajućih vrsta na detekciju honokiola, kao i praktična upotrebljivost senzora za analizu realnih uzoraka čime je utvrđeno da razvijen pristup pokazuje veliku tačnost, selektivnost i reproduktivnost. Zahvaljujući niskoj granici detekcije i širokom radnom opsegu, predložena senzorska platforma otvara mogućnosti za konstrukciju senzora za detekciju i praćenje koncentracije honokiola u farmaceutskoj industriji i istraživanjima u medicinskoj hemiji.",
title = "Uticaj veličine čestica bizmut oksida na elektrokatalitičke osobine materijala",
pages = "1-39"
}
Knežević, S.. (2021). Uticaj veličine čestica bizmut oksida na elektrokatalitičke osobine materijala. , 1-39.
Knežević S. Uticaj veličine čestica bizmut oksida na elektrokatalitičke osobine materijala. 2021;:1-39..
Knežević, Sara, "Uticaj veličine čestica bizmut oksida na elektrokatalitičke osobine materijala" (2021):1-39.

A single drop histamine sensor based on AuNPs/MnO2 modified screen-printed electrode

Knežević, Sara; Ognjanović, Miloš; Nedić, Nemanja; Mariano, José F.M.L.; Milanović, Zorana; Petković, Branka B.; Antić, Bratislav; Vranješ-Đurić, Sanja; Stanković, Dalibor

(Elsevier, 2020)

TY  - JOUR
AU  - Knežević, Sara
AU  - Ognjanović, Miloš
AU  - Nedić, Nemanja
AU  - Mariano, José F.M.L.
AU  - Milanović, Zorana
AU  - Petković, Branka B.
AU  - Antić, Bratislav
AU  - Vranješ-Đurić, Sanja
AU  - Stanković, Dalibor
PY  - 2020
UR  - https://cherry.chem.bg.ac.rs/handle/123456789/3880
AB  - In order to ensure high food quality, one of the prime importance is the detection and quantification of histamine, well known marine food poison. In this work, we constructed novel electrochemical biosensor for the detection of histamine based on gold nanoparticles decorated on manganese dioxide (Au/MnO2) and used for modification of screen-printed carbon electrode (Au/MnO2@SPCE). The constructed sensor was then used for the estimation of histamine content in a single drop. Materials used in this study were synthesized and characterized using HR-TEM, XRPD and electrochemical methods. The amperometric detection method was optimized and, under selected operating parameters (supporting electrolyte pH 6, working potential of 1 V), the proposed sensor possesses linear working range from 0.3 µM to 5.1 µM, with a detection limit of 0.08 µM. The effect of selected interferences was investigated and it was found that the developed approach offers accurate, precise, selective, fast and reproducible quantification of histamine using only one drop of the sample. In the end, this work stands as a proof-of-concept of the modified electrodes and electrochemical detection as a promising and prospective approach for the applications in real-time monitoring of the food quality.
PB  - Elsevier
T2  - Microchemical Journal
T1  - A single drop histamine sensor based on AuNPs/MnO2 modified screen-printed electrode
VL  - 155
DO  - 10.1016/j.microc.2020.104778
ER  - 
@article{
author = "Knežević, Sara and Ognjanović, Miloš and Nedić, Nemanja and Mariano, José F.M.L. and Milanović, Zorana and Petković, Branka B. and Antić, Bratislav and Vranješ-Đurić, Sanja and Stanković, Dalibor",
year = "2020",
abstract = "In order to ensure high food quality, one of the prime importance is the detection and quantification of histamine, well known marine food poison. In this work, we constructed novel electrochemical biosensor for the detection of histamine based on gold nanoparticles decorated on manganese dioxide (Au/MnO2) and used for modification of screen-printed carbon electrode (Au/MnO2@SPCE). The constructed sensor was then used for the estimation of histamine content in a single drop. Materials used in this study were synthesized and characterized using HR-TEM, XRPD and electrochemical methods. The amperometric detection method was optimized and, under selected operating parameters (supporting electrolyte pH 6, working potential of 1 V), the proposed sensor possesses linear working range from 0.3 µM to 5.1 µM, with a detection limit of 0.08 µM. The effect of selected interferences was investigated and it was found that the developed approach offers accurate, precise, selective, fast and reproducible quantification of histamine using only one drop of the sample. In the end, this work stands as a proof-of-concept of the modified electrodes and electrochemical detection as a promising and prospective approach for the applications in real-time monitoring of the food quality.",
publisher = "Elsevier",
journal = "Microchemical Journal",
title = "A single drop histamine sensor based on AuNPs/MnO2 modified screen-printed electrode",
volume = "155",
doi = "10.1016/j.microc.2020.104778"
}
Knežević, S., Ognjanović, M., Nedić, N., Mariano, J. F.M.L., Milanović, Z., Petković, B. B., Antić, B., Vranješ-Đurić, S.,& Stanković, D.. (2020). A single drop histamine sensor based on AuNPs/MnO2 modified screen-printed electrode. in Microchemical Journal
Elsevier., 155.
https://doi.org/10.1016/j.microc.2020.104778
Knežević S, Ognjanović M, Nedić N, Mariano JF, Milanović Z, Petković BB, Antić B, Vranješ-Đurić S, Stanković D. A single drop histamine sensor based on AuNPs/MnO2 modified screen-printed electrode. in Microchemical Journal. 2020;155.
doi:10.1016/j.microc.2020.104778 .
Knežević, Sara, Ognjanović, Miloš, Nedić, Nemanja, Mariano, José F.M.L., Milanović, Zorana, Petković, Branka B., Antić, Bratislav, Vranješ-Đurić, Sanja, Stanković, Dalibor, "A single drop histamine sensor based on AuNPs/MnO2 modified screen-printed electrode" in Microchemical Journal, 155 (2020),
https://doi.org/10.1016/j.microc.2020.104778 . .
1
8
6
7

TiO2/APTES cross-linked to carboxylic graphene based impedimetric glucose biosensor

Ognjanović, Miloš; Stanković, Vesna; Knežević, Sara; Antić, Bratislav; Vranješ-Đurić, Sanja; Stanković, Dalibor

(Elsevier, 2020)

TY  - JOUR
AU  - Ognjanović, Miloš
AU  - Stanković, Vesna
AU  - Knežević, Sara
AU  - Antić, Bratislav
AU  - Vranješ-Đurić, Sanja
AU  - Stanković, Dalibor
PY  - 2020
UR  - https://cherry.chem.bg.ac.rs/handle/123456789/4023
AB  - Herein, we proposed a novel approach and state-of-the-art technology for the improvement of the materials and enzyme immobilization at the electrode surface and construction of impedimetric glucose biosensor. We silanized titanium dioxide nanoparticles using (3-aminopropyl)triethoxysilane (APTES), for the preparation of cross-linked material nanoparticles, with carboxylic graphene. The silanization of titanium dioxide nanoparticles and an increase in electron shuttle was proven feasible when this composite was able to achieve about 30% higher current than non-silanized material. The proposed approach was used for the modification of the printed three-electrode system and the development of the impedimetric glucose biosensor. The material morphology and electrochemical characteristics were confirmed by spectroscopic and electrochemical methods. The present combination effectively modified the electrode surface and serve as a promising basis for the construction of Point-of-Care devices. Developed biosensor possesses wide operating linear range toward glucose detection from 50 µmol to 1000 µmol, with the limit of detection of 24 µmol. Finally, negligible interference effect and application in the real sample indicate that the proposed mechanism can be successfully applied to the assessment of glucose level in only one drop of real sample.
PB  - Elsevier
T2  - Microchemical Journal
T1  - TiO2/APTES cross-linked to carboxylic graphene based impedimetric glucose biosensor
VL  - 158
DO  - 10.1016/j.microc.2020.105150
ER  - 
@article{
author = "Ognjanović, Miloš and Stanković, Vesna and Knežević, Sara and Antić, Bratislav and Vranješ-Đurić, Sanja and Stanković, Dalibor",
year = "2020",
abstract = "Herein, we proposed a novel approach and state-of-the-art technology for the improvement of the materials and enzyme immobilization at the electrode surface and construction of impedimetric glucose biosensor. We silanized titanium dioxide nanoparticles using (3-aminopropyl)triethoxysilane (APTES), for the preparation of cross-linked material nanoparticles, with carboxylic graphene. The silanization of titanium dioxide nanoparticles and an increase in electron shuttle was proven feasible when this composite was able to achieve about 30% higher current than non-silanized material. The proposed approach was used for the modification of the printed three-electrode system and the development of the impedimetric glucose biosensor. The material morphology and electrochemical characteristics were confirmed by spectroscopic and electrochemical methods. The present combination effectively modified the electrode surface and serve as a promising basis for the construction of Point-of-Care devices. Developed biosensor possesses wide operating linear range toward glucose detection from 50 µmol to 1000 µmol, with the limit of detection of 24 µmol. Finally, negligible interference effect and application in the real sample indicate that the proposed mechanism can be successfully applied to the assessment of glucose level in only one drop of real sample.",
publisher = "Elsevier",
journal = "Microchemical Journal",
title = "TiO2/APTES cross-linked to carboxylic graphene based impedimetric glucose biosensor",
volume = "158",
doi = "10.1016/j.microc.2020.105150"
}
Ognjanović, M., Stanković, V., Knežević, S., Antić, B., Vranješ-Đurić, S.,& Stanković, D.. (2020). TiO2/APTES cross-linked to carboxylic graphene based impedimetric glucose biosensor. in Microchemical Journal
Elsevier., 158.
https://doi.org/10.1016/j.microc.2020.105150
Ognjanović M, Stanković V, Knežević S, Antić B, Vranješ-Đurić S, Stanković D. TiO2/APTES cross-linked to carboxylic graphene based impedimetric glucose biosensor. in Microchemical Journal. 2020;158.
doi:10.1016/j.microc.2020.105150 .
Ognjanović, Miloš, Stanković, Vesna, Knežević, Sara, Antić, Bratislav, Vranješ-Đurić, Sanja, Stanković, Dalibor, "TiO2/APTES cross-linked to carboxylic graphene based impedimetric glucose biosensor" in Microchemical Journal, 158 (2020),
https://doi.org/10.1016/j.microc.2020.105150 . .
7
4
6

Impedimetrijski biosenzor za detekciju homocisteina baziran na S-Adenozil-L-Homocistein hidrolazi imobilisanoj na elektrodi modifikovanoj galijum oksidom i SWCNTs

Knežević, Sara

(2020)

TY  - THES
AU  - Knežević, Sara
PY  - 2020
UR  - https://cherry.chem.bg.ac.rs/handle/123456789/4096
AB  - Hronična oboljenja karakteristična za stariju populaciju često su posledica povišenog nivoa homocisteina u telesnim tečnostima. Radi prevencije pojave bolesti neophodno je razviti brzu, jednostavnu i pouzdanu metodu za detekciju homocisteina, uz minimalnu prethodnu obradu uzorka. U ovom radu razvijen je nov pristup za impedimetrijsku detekciju homocisteina, baziran na upotrebi hidrolitičkog enzima S-Adenozil-L-Homocistein hidrolaza (SAH), koji je imobilisan na kompozitnom materijalu - nanočestice galijum oksida stabilizovane citratom i dispergovane na jednozidnim ugljeničnim nanocevima (CA/Ga2O3@SWCNTs). Kompozitni materijal je korišćen za modifikaciju površine štampane elektrode. Na taj način je dobijena selektivna, osetljiva i pouzdana patforma za detekciju homocisteina, sa granicom detekcije (LOD) 0.17 μM i linearnim radnim opegom od 1 do 44 μM. Stabilnost Ga2O3 je povećana oblaganjem citratima, a problem električne anizotropije prevaziđen građenjem kompozita sa jednozidnim ugljeničnim nanocevima (single walled carbon nanotubes - SWCNTs). Ovaj kompozit se pokazao kao stabilna podloga za imobilizaciju enzima. Karakterišu ga katalitičke osobine u reakciji prenosa elektrona i reakciji oksidacije homocisteina. Dobijen sistem nije podložan smetnjama koje potiču od interferenata iz biološkog matriksa, a sama elektroda poseduje veliku stabilnost i reproduktivnost. Praktična upotrebljivost senzora je dokazana izvođenjem merenja u realnim uzorcima. Predložen biosenzor predstavlja odličan alat za praćenje nivoa homocisteina, koji je pogodan za upotrebu u kliničkoj praksi i ima veliki potencijal za prevenciju pojave različitih i ozbiljnih oboljenja.
T1  - Impedimetrijski biosenzor za detekciju homocisteina baziran na S-Adenozil-L-Homocistein hidrolazi imobilisanoj na elektrodi modifikovanoj galijum oksidom i SWCNTs
SP  - 1
EP  - 28
ER  - 
@misc{
author = "Knežević, Sara",
year = "2020",
abstract = "Hronična oboljenja karakteristična za stariju populaciju često su posledica povišenog nivoa homocisteina u telesnim tečnostima. Radi prevencije pojave bolesti neophodno je razviti brzu, jednostavnu i pouzdanu metodu za detekciju homocisteina, uz minimalnu prethodnu obradu uzorka. U ovom radu razvijen je nov pristup za impedimetrijsku detekciju homocisteina, baziran na upotrebi hidrolitičkog enzima S-Adenozil-L-Homocistein hidrolaza (SAH), koji je imobilisan na kompozitnom materijalu - nanočestice galijum oksida stabilizovane citratom i dispergovane na jednozidnim ugljeničnim nanocevima (CA/Ga2O3@SWCNTs). Kompozitni materijal je korišćen za modifikaciju površine štampane elektrode. Na taj način je dobijena selektivna, osetljiva i pouzdana patforma za detekciju homocisteina, sa granicom detekcije (LOD) 0.17 μM i linearnim radnim opegom od 1 do 44 μM. Stabilnost Ga2O3 je povećana oblaganjem citratima, a problem električne anizotropije prevaziđen građenjem kompozita sa jednozidnim ugljeničnim nanocevima (single walled carbon nanotubes - SWCNTs). Ovaj kompozit se pokazao kao stabilna podloga za imobilizaciju enzima. Karakterišu ga katalitičke osobine u reakciji prenosa elektrona i reakciji oksidacije homocisteina. Dobijen sistem nije podložan smetnjama koje potiču od interferenata iz biološkog matriksa, a sama elektroda poseduje veliku stabilnost i reproduktivnost. Praktična upotrebljivost senzora je dokazana izvođenjem merenja u realnim uzorcima. Predložen biosenzor predstavlja odličan alat za praćenje nivoa homocisteina, koji je pogodan za upotrebu u kliničkoj praksi i ima veliki potencijal za prevenciju pojave različitih i ozbiljnih oboljenja.",
title = "Impedimetrijski biosenzor za detekciju homocisteina baziran na S-Adenozil-L-Homocistein hidrolazi imobilisanoj na elektrodi modifikovanoj galijum oksidom i SWCNTs",
pages = "1-28"
}
Knežević, S.. (2020). Impedimetrijski biosenzor za detekciju homocisteina baziran na S-Adenozil-L-Homocistein hidrolazi imobilisanoj na elektrodi modifikovanoj galijum oksidom i SWCNTs. , 1-28.
Knežević S. Impedimetrijski biosenzor za detekciju homocisteina baziran na S-Adenozil-L-Homocistein hidrolazi imobilisanoj na elektrodi modifikovanoj galijum oksidom i SWCNTs. 2020;:1-28..
Knežević, Sara, "Impedimetrijski biosenzor za detekciju homocisteina baziran na S-Adenozil-L-Homocistein hidrolazi imobilisanoj na elektrodi modifikovanoj galijum oksidom i SWCNTs" (2020):1-28.