Mladenović, Aleksandar

Link to this page

Authority KeyName Variants
orcid::0000-0001-6188-2551
  • Mladenović, Aleksandar (1)
Projects

Author's Bibliography

Electrochemical determination of sertraline in pharmaceutical formulation and serum using a gold electrode in a pH 8.4 bicarbonate solution

Lović, Jelena; Lađarević, Jelena; Trišović, Nemanja; Andrić, Filip; Mladenović, Aleksandar; Mijin, Dušan; Vuković, Dragan; Petrović, Slobodan D.; Avramov Ivić, Milka

(Springer International Publishing, 2021)

TY  - JOUR
AU  - Lović, Jelena
AU  - Lađarević, Jelena
AU  - Trišović, Nemanja
AU  - Andrić, Filip
AU  - Mladenović, Aleksandar
AU  - Mijin, Dušan
AU  - Vuković, Dragan
AU  - Petrović, Slobodan D.
AU  - Avramov Ivić, Milka
PY  - 2021
UR  - https://cherry.chem.bg.ac.rs/handle/123456789/4419
AB  - The electrochemical characterization of sertraline at gold electrode was examined by cyclic voltammetry measurements (CV) in pH 8.4 bicarbonate buffer. Then Au electrode was evaluated for the quantitative determination of sertraline using square wave voltammetry (SWV). To enhance the sensitivity during the drug determination, (2-hydroxypropyl)-β-cyclodextrin (HPβCD) and β-cyclodextrin (βCD) inclusion complexes were employed. Using the proposed SWV technique, the anodic current peak was linear within a concentration range of 0.1–0.5 µM with a limit of detection (LOD) of 2.0 × 10–8 M and a limit of quantification (LOQ) of 6.7 × 10–8 M. In the case of inclusion complex of the sertraline with HPβCD, a good linearity range of 0.1–0.9 µM was obtained with a LOD of 2.6 × 10–8 M and a LOQ of 8.8 × 10–8 M. The gold electrode revealed the same linearity range for inclusion complex of the sertraline with βCD with a LOD and a LOQ being 2.6 × 10–8 and 8.6 × 10–8 M, respectively. Comparing the regression equations, it can be concluded that the sensitivity in the presence of inclusion complex can be up to 5 times higher. The applicability of the developed method was confirmed by the analysis of this drug in pharmaceutical formulation and in human serum spiked with sertraline standard. The comparison to HPLC method was successfully performed.
PB  - Springer International Publishing
T2  - Monatshefte für Chemie - Chemical Monthly
T2  - Monatshefte für Chemie - Chemical MonthlyMonatsh Chem
T1  - Electrochemical determination of sertraline in pharmaceutical formulation and serum using a gold electrode in a pH 8.4 bicarbonate solution
VL  - 152
IS  - 2
SP  - 185
EP  - 192
DO  - 10.1007/s00706-021-02745-3
ER  - 
@article{
author = "Lović, Jelena and Lađarević, Jelena and Trišović, Nemanja and Andrić, Filip and Mladenović, Aleksandar and Mijin, Dušan and Vuković, Dragan and Petrović, Slobodan D. and Avramov Ivić, Milka",
year = "2021",
abstract = "The electrochemical characterization of sertraline at gold electrode was examined by cyclic voltammetry measurements (CV) in pH 8.4 bicarbonate buffer. Then Au electrode was evaluated for the quantitative determination of sertraline using square wave voltammetry (SWV). To enhance the sensitivity during the drug determination, (2-hydroxypropyl)-β-cyclodextrin (HPβCD) and β-cyclodextrin (βCD) inclusion complexes were employed. Using the proposed SWV technique, the anodic current peak was linear within a concentration range of 0.1–0.5 µM with a limit of detection (LOD) of 2.0 × 10–8 M and a limit of quantification (LOQ) of 6.7 × 10–8 M. In the case of inclusion complex of the sertraline with HPβCD, a good linearity range of 0.1–0.9 µM was obtained with a LOD of 2.6 × 10–8 M and a LOQ of 8.8 × 10–8 M. The gold electrode revealed the same linearity range for inclusion complex of the sertraline with βCD with a LOD and a LOQ being 2.6 × 10–8 and 8.6 × 10–8 M, respectively. Comparing the regression equations, it can be concluded that the sensitivity in the presence of inclusion complex can be up to 5 times higher. The applicability of the developed method was confirmed by the analysis of this drug in pharmaceutical formulation and in human serum spiked with sertraline standard. The comparison to HPLC method was successfully performed.",
publisher = "Springer International Publishing",
journal = "Monatshefte für Chemie - Chemical Monthly, Monatshefte für Chemie - Chemical MonthlyMonatsh Chem",
title = "Electrochemical determination of sertraline in pharmaceutical formulation and serum using a gold electrode in a pH 8.4 bicarbonate solution",
volume = "152",
number = "2",
pages = "185-192",
doi = "10.1007/s00706-021-02745-3"
}
Lović, J., Lađarević, J., Trišović, N., Andrić, F., Mladenović, A., Mijin, D., Vuković, D., Petrović, S. D.,& Avramov Ivić, M.. (2021). Electrochemical determination of sertraline in pharmaceutical formulation and serum using a gold electrode in a pH 8.4 bicarbonate solution. in Monatshefte für Chemie - Chemical Monthly
Springer International Publishing., 152(2), 185-192.
https://doi.org/10.1007/s00706-021-02745-3
Lović J, Lađarević J, Trišović N, Andrić F, Mladenović A, Mijin D, Vuković D, Petrović SD, Avramov Ivić M. Electrochemical determination of sertraline in pharmaceutical formulation and serum using a gold electrode in a pH 8.4 bicarbonate solution. in Monatshefte für Chemie - Chemical Monthly. 2021;152(2):185-192.
doi:10.1007/s00706-021-02745-3 .
Lović, Jelena, Lađarević, Jelena, Trišović, Nemanja, Andrić, Filip, Mladenović, Aleksandar, Mijin, Dušan, Vuković, Dragan, Petrović, Slobodan D., Avramov Ivić, Milka, "Electrochemical determination of sertraline in pharmaceutical formulation and serum using a gold electrode in a pH 8.4 bicarbonate solution" in Monatshefte für Chemie - Chemical Monthly, 152, no. 2 (2021):185-192,
https://doi.org/10.1007/s00706-021-02745-3 . .
5
1
5
4