Grant scheme for Support of Young Researchers and Excellent Teams of Young Researchers

Link to this page

Grant scheme for Support of Young Researchers and Excellent Teams of Young Researchers

Authors

Publications

Supplementary data for article: Šovrc, Ľ.; Borovska, K.; Cinková, K.; Stanković, D.; Planková, A. Advanced Electrochemical Platform for Determination of Cytostatic Drug Flutamide in Various Matrices Using a Boron-Doped Diamond Electrode. Electrochimica Acta 2017, 251, 621–630. https://doi.org/10.1016/j.electacta.2017.08.077

Šovrc, Ľubomír; Borovska, Katarina; Cinková, Kristína; Stanković, Dalibor; Planková, Alexandra

(Pergamon-Elsevier Science Ltd, Oxford, 2017)

TY  - DATA
AU  - Šovrc, Ľubomír
AU  - Borovska, Katarina
AU  - Cinková, Kristína
AU  - Stanković, Dalibor
AU  - Planková, Alexandra
PY  - 2017
UR  - https://cherry.chem.bg.ac.rs/handle/123456789/2997
PB  - Pergamon-Elsevier Science Ltd, Oxford
T2  - Electrochimica Acta
T1  - Supplementary data for article: Šovrc, Ľ.; Borovska, K.; Cinková, K.; Stanković, D.; Planková, A. Advanced Electrochemical Platform for Determination of Cytostatic Drug Flutamide in Various Matrices Using a Boron-Doped Diamond Electrode. Electrochimica Acta 2017, 251, 621–630. https://doi.org/10.1016/j.electacta.2017.08.077
UR  - https://hdl.handle.net/21.15107/rcub_cherry_2997
ER  - 
@misc{
author = "Šovrc, Ľubomír and Borovska, Katarina and Cinková, Kristína and Stanković, Dalibor and Planková, Alexandra",
year = "2017",
publisher = "Pergamon-Elsevier Science Ltd, Oxford",
journal = "Electrochimica Acta",
title = "Supplementary data for article: Šovrc, Ľ.; Borovska, K.; Cinková, K.; Stanković, D.; Planková, A. Advanced Electrochemical Platform for Determination of Cytostatic Drug Flutamide in Various Matrices Using a Boron-Doped Diamond Electrode. Electrochimica Acta 2017, 251, 621–630. https://doi.org/10.1016/j.electacta.2017.08.077",
url = "https://hdl.handle.net/21.15107/rcub_cherry_2997"
}
Šovrc, Ľ., Borovska, K., Cinková, K., Stanković, D.,& Planková, A.. (2017). Supplementary data for article: Šovrc, Ľ.; Borovska, K.; Cinková, K.; Stanković, D.; Planková, A. Advanced Electrochemical Platform for Determination of Cytostatic Drug Flutamide in Various Matrices Using a Boron-Doped Diamond Electrode. Electrochimica Acta 2017, 251, 621–630. https://doi.org/10.1016/j.electacta.2017.08.077. in Electrochimica Acta
Pergamon-Elsevier Science Ltd, Oxford..
https://hdl.handle.net/21.15107/rcub_cherry_2997
Šovrc Ľ, Borovska K, Cinková K, Stanković D, Planková A. Supplementary data for article: Šovrc, Ľ.; Borovska, K.; Cinková, K.; Stanković, D.; Planková, A. Advanced Electrochemical Platform for Determination of Cytostatic Drug Flutamide in Various Matrices Using a Boron-Doped Diamond Electrode. Electrochimica Acta 2017, 251, 621–630. https://doi.org/10.1016/j.electacta.2017.08.077. in Electrochimica Acta. 2017;.
https://hdl.handle.net/21.15107/rcub_cherry_2997 .
Šovrc, Ľubomír, Borovska, Katarina, Cinková, Kristína, Stanković, Dalibor, Planková, Alexandra, "Supplementary data for article: Šovrc, Ľ.; Borovska, K.; Cinková, K.; Stanković, D.; Planková, A. Advanced Electrochemical Platform for Determination of Cytostatic Drug Flutamide in Various Matrices Using a Boron-Doped Diamond Electrode. Electrochimica Acta 2017, 251, 621–630. https://doi.org/10.1016/j.electacta.2017.08.077" in Electrochimica Acta (2017),
https://hdl.handle.net/21.15107/rcub_cherry_2997 .

Advanced electrochemical platform for determination of cytostatic drug flutamide in various matrices using a boron-doped diamond electrode

Šovrc, Ľubomír; Borovska, Katarina; Cinková, Kristína; Stanković, Dalibor; Planková, Alexandra

(Pergamon-Elsevier Science Ltd, Oxford, 2017)

TY  - JOUR
AU  - Šovrc, Ľubomír
AU  - Borovska, Katarina
AU  - Cinková, Kristína
AU  - Stanković, Dalibor
AU  - Planková, Alexandra
PY  - 2017
UR  - https://cherry.chem.bg.ac.rs/handle/123456789/2996
AB  - An innovative, rapid and simple electrochemical approach for the reliable quantification of cytostatic drug flutamide (FLU) in various matrices is herein proposed. This platform involves coupling of differential pulse (DPV) and square-wave voltammetry (SWV) with a boron-doped diamond (BDD) electrode as the working electrode and 0.1 M sulphuric acid as the supporting electrolyte. For the first time, the voltammetric profile of FLU was manifested by three irreversible and diffusion-controlled oxidation peaks at + 1.1 (P1), + 1.4 (P2) and + 1.9 V (P3). The analytical performance evaluation was assessed for all three peaks, using both pulse voltammetric techniques with the optimized operating parameters and the highest sensitivity of 1.76 nA/mu M was accomplished for P2 using DPV and 3.54 nA/mu M for P3 using SWV. The corresponding linear concentration ranges were found to be 0.99-42.9 and 4.8-35.5 mu M with the detection limits of 0.42 and 0.18 mu M, respectively. The repeatability varied, depending on the oxidation peaks of FLU, with the relative standard deviations in the range of 3.3-8.8% and 2.9-9.3% for DPV and SWV, respectively. The proposed electrochemical platform was successfully applied in the analysis of pharmaceutical formulations, spiked human urine and water samples with the significant mean recoveries. Using BDD electrode, the current work establishes an advanced, simple and rapid alternative platform to so far used toxic mercury-based electrodes and time demanding chemically modified electrodes in cytostatic sensing. Besides, BDD electrode represents a comfortable electrochemical sensor for routine analysis in pharmaceutical, clinical and environmental chemistry.
PB  - Pergamon-Elsevier Science Ltd, Oxford
T2  - Electrochimica Acta
T1  - Advanced electrochemical platform for determination of cytostatic drug flutamide in various matrices using a boron-doped diamond electrode
VL  - 251
SP  - 621
EP  - 630
DO  - 10.1016/j.electacta.2017.08.077
ER  - 
@article{
author = "Šovrc, Ľubomír and Borovska, Katarina and Cinková, Kristína and Stanković, Dalibor and Planková, Alexandra",
year = "2017",
abstract = "An innovative, rapid and simple electrochemical approach for the reliable quantification of cytostatic drug flutamide (FLU) in various matrices is herein proposed. This platform involves coupling of differential pulse (DPV) and square-wave voltammetry (SWV) with a boron-doped diamond (BDD) electrode as the working electrode and 0.1 M sulphuric acid as the supporting electrolyte. For the first time, the voltammetric profile of FLU was manifested by three irreversible and diffusion-controlled oxidation peaks at + 1.1 (P1), + 1.4 (P2) and + 1.9 V (P3). The analytical performance evaluation was assessed for all three peaks, using both pulse voltammetric techniques with the optimized operating parameters and the highest sensitivity of 1.76 nA/mu M was accomplished for P2 using DPV and 3.54 nA/mu M for P3 using SWV. The corresponding linear concentration ranges were found to be 0.99-42.9 and 4.8-35.5 mu M with the detection limits of 0.42 and 0.18 mu M, respectively. The repeatability varied, depending on the oxidation peaks of FLU, with the relative standard deviations in the range of 3.3-8.8% and 2.9-9.3% for DPV and SWV, respectively. The proposed electrochemical platform was successfully applied in the analysis of pharmaceutical formulations, spiked human urine and water samples with the significant mean recoveries. Using BDD electrode, the current work establishes an advanced, simple and rapid alternative platform to so far used toxic mercury-based electrodes and time demanding chemically modified electrodes in cytostatic sensing. Besides, BDD electrode represents a comfortable electrochemical sensor for routine analysis in pharmaceutical, clinical and environmental chemistry.",
publisher = "Pergamon-Elsevier Science Ltd, Oxford",
journal = "Electrochimica Acta",
title = "Advanced electrochemical platform for determination of cytostatic drug flutamide in various matrices using a boron-doped diamond electrode",
volume = "251",
pages = "621-630",
doi = "10.1016/j.electacta.2017.08.077"
}
Šovrc, Ľ., Borovska, K., Cinková, K., Stanković, D.,& Planková, A.. (2017). Advanced electrochemical platform for determination of cytostatic drug flutamide in various matrices using a boron-doped diamond electrode. in Electrochimica Acta
Pergamon-Elsevier Science Ltd, Oxford., 251, 621-630.
https://doi.org/10.1016/j.electacta.2017.08.077
Šovrc Ľ, Borovska K, Cinková K, Stanković D, Planková A. Advanced electrochemical platform for determination of cytostatic drug flutamide in various matrices using a boron-doped diamond electrode. in Electrochimica Acta. 2017;251:621-630.
doi:10.1016/j.electacta.2017.08.077 .
Šovrc, Ľubomír, Borovska, Katarina, Cinková, Kristína, Stanković, Dalibor, Planková, Alexandra, "Advanced electrochemical platform for determination of cytostatic drug flutamide in various matrices using a boron-doped diamond electrode" in Electrochimica Acta, 251 (2017):621-630,
https://doi.org/10.1016/j.electacta.2017.08.077 . .
73
55
78
65

Advanced electrochemical platform for determination of cytostatic drug flutamide in various matrices using a boron-doped diamond electrode

Šovrc, Ľubomír; Borovska, Katarina; Cinková, Kristína; Stanković, Dalibor; Planková, Alexandra

(Pergamon-Elsevier Science Ltd, Oxford, 2017)

TY  - JOUR
AU  - Šovrc, Ľubomír
AU  - Borovska, Katarina
AU  - Cinková, Kristína
AU  - Stanković, Dalibor
AU  - Planková, Alexandra
PY  - 2017
UR  - https://cherry.chem.bg.ac.rs/handle/123456789/2540
AB  - An innovative, rapid and simple electrochemical approach for the reliable quantification of cytostatic drug flutamide (FLU) in various matrices is herein proposed. This platform involves coupling of differential pulse (DPV) and square-wave voltammetry (SWV) with a boron-doped diamond (BDD) electrode as the working electrode and 0.1 M sulphuric acid as the supporting electrolyte. For the first time, the voltammetric profile of FLU was manifested by three irreversible and diffusion-controlled oxidation peaks at + 1.1 (P1), + 1.4 (P2) and + 1.9 V (P3). The analytical performance evaluation was assessed for all three peaks, using both pulse voltammetric techniques with the optimized operating parameters and the highest sensitivity of 1.76 nA/mu M was accomplished for P2 using DPV and 3.54 nA/mu M for P3 using SWV. The corresponding linear concentration ranges were found to be 0.99-42.9 and 4.8-35.5 mu M with the detection limits of 0.42 and 0.18 mu M, respectively. The repeatability varied, depending on the oxidation peaks of FLU, with the relative standard deviations in the range of 3.3-8.8% and 2.9-9.3% for DPV and SWV, respectively. The proposed electrochemical platform was successfully applied in the analysis of pharmaceutical formulations, spiked human urine and water samples with the significant mean recoveries. Using BDD electrode, the current work establishes an advanced, simple and rapid alternative platform to so far used toxic mercury-based electrodes and time demanding chemically modified electrodes in cytostatic sensing. Besides, BDD electrode represents a comfortable electrochemical sensor for routine analysis in pharmaceutical, clinical and environmental chemistry. (C) 2017 Elsevier Ltd. All rights reserved.
PB  - Pergamon-Elsevier Science Ltd, Oxford
T2  - Electrochimica Acta
T1  - Advanced electrochemical platform for determination of cytostatic drug flutamide in various matrices using a boron-doped diamond electrode
VL  - 251
SP  - 621
EP  - 630
DO  - 10.1016/j.electacta.2017.08.077
ER  - 
@article{
author = "Šovrc, Ľubomír and Borovska, Katarina and Cinková, Kristína and Stanković, Dalibor and Planková, Alexandra",
year = "2017",
abstract = "An innovative, rapid and simple electrochemical approach for the reliable quantification of cytostatic drug flutamide (FLU) in various matrices is herein proposed. This platform involves coupling of differential pulse (DPV) and square-wave voltammetry (SWV) with a boron-doped diamond (BDD) electrode as the working electrode and 0.1 M sulphuric acid as the supporting electrolyte. For the first time, the voltammetric profile of FLU was manifested by three irreversible and diffusion-controlled oxidation peaks at + 1.1 (P1), + 1.4 (P2) and + 1.9 V (P3). The analytical performance evaluation was assessed for all three peaks, using both pulse voltammetric techniques with the optimized operating parameters and the highest sensitivity of 1.76 nA/mu M was accomplished for P2 using DPV and 3.54 nA/mu M for P3 using SWV. The corresponding linear concentration ranges were found to be 0.99-42.9 and 4.8-35.5 mu M with the detection limits of 0.42 and 0.18 mu M, respectively. The repeatability varied, depending on the oxidation peaks of FLU, with the relative standard deviations in the range of 3.3-8.8% and 2.9-9.3% for DPV and SWV, respectively. The proposed electrochemical platform was successfully applied in the analysis of pharmaceutical formulations, spiked human urine and water samples with the significant mean recoveries. Using BDD electrode, the current work establishes an advanced, simple and rapid alternative platform to so far used toxic mercury-based electrodes and time demanding chemically modified electrodes in cytostatic sensing. Besides, BDD electrode represents a comfortable electrochemical sensor for routine analysis in pharmaceutical, clinical and environmental chemistry. (C) 2017 Elsevier Ltd. All rights reserved.",
publisher = "Pergamon-Elsevier Science Ltd, Oxford",
journal = "Electrochimica Acta",
title = "Advanced electrochemical platform for determination of cytostatic drug flutamide in various matrices using a boron-doped diamond electrode",
volume = "251",
pages = "621-630",
doi = "10.1016/j.electacta.2017.08.077"
}
Šovrc, Ľ., Borovska, K., Cinková, K., Stanković, D.,& Planková, A.. (2017). Advanced electrochemical platform for determination of cytostatic drug flutamide in various matrices using a boron-doped diamond electrode. in Electrochimica Acta
Pergamon-Elsevier Science Ltd, Oxford., 251, 621-630.
https://doi.org/10.1016/j.electacta.2017.08.077
Šovrc Ľ, Borovska K, Cinková K, Stanković D, Planková A. Advanced electrochemical platform for determination of cytostatic drug flutamide in various matrices using a boron-doped diamond electrode. in Electrochimica Acta. 2017;251:621-630.
doi:10.1016/j.electacta.2017.08.077 .
Šovrc, Ľubomír, Borovska, Katarina, Cinková, Kristína, Stanković, Dalibor, Planková, Alexandra, "Advanced electrochemical platform for determination of cytostatic drug flutamide in various matrices using a boron-doped diamond electrode" in Electrochimica Acta, 251 (2017):621-630,
https://doi.org/10.1016/j.electacta.2017.08.077 . .
73
55
78
65