Boron-doped diamond electrode - A prestigious unmodified carbon electrode for simple and fast determination of bentazone in river water samples

Thumbnail
2018
Boron-doped_diamond_acc_2018.pdf (1.307Mb)
Authors
Jevtić, Sonja
Stefanović, Anđela
Stanković, Dalibor
Pergal, Marija V.
Ivanović, Aleksandra T.
Jokić, Anja
Petković, Branka B.
Article (Accepted Version)
Metadata
Show full item record
Abstract
Bentazone (BZ) is selective contact-past herbicide with suspected reproductive toxicity potential for human due to possible contamination of ground and surface waters. This work presents simple, rapid, sensitive and accurate determination of bentazone at unmodified boron-doped diamond electrode, using differential pulse voltammetry in Britton-Robinson buffer (pH 4, oxidation peak at 1.0 V). Under optimized DPV conditions linear calibration curve was obtained for range of 2 to 100 mu M, with a detection limit of 0.5 mu M. The effect of possible interfering agents is negligible, confirming good selectivity of the method. The method was successfully applied to determination of bentazone in spiked river water samples. This electrochemical determination of bentazone represents a favorable alternative to other used time-consuming and expensive analytical techniques and procedures.
Keywords:
Bentazone determination / Electrochemical method / Voltanunetry / River water samples
Source:
Diamond and Related Materials, 2018, 81, 133-137
Publisher:
  • Elsevier Science Sa, Lausanne
Funding / projects:
  • Multiscale structuring of polymer nanocomposites and functional materials based on different precursors (RS-45022)
  • Application of advanced oxidation processes and nanostructured oxide materials for the removal of pollutants from the environment, development and optimisation of instrumental techniques for efficiency monitoring (RS-172030)
  • Strengthening of the MagBioVin Research and Innovation Team for Development of Novel Approaches for Tumour Therapy based on Nanostructured Materials (EU-621375)
Note:
  • This is peer-reviewed version of the following article: Jevtić, S.; Stefanović, A.; Stanković, D. M.; Pergal, M. V.; Ivanović, A. T.; Jokić, A.; Petković, B. B. Boron-Doped Diamond Electrode — A Prestigious Unmodified Carbon Electrode for Simple and Fast Determination of Bentazone in River Water Samples. Diamond and Related Materials 2018, 81, 133–137. https://doi.org/10.1016/j.diamond.2017.12.009
  • Supplementary material: http://cherry.chem.bg.ac.rs/handle/123456789/3178

DOI: 10.1016/j.diamond.2017.12.009

ISSN: 0925-9635

WoS: 000424310600018

Scopus: 2-s2.0-85037548233
[ Google Scholar ]
33
25
URI
https://cherry.chem.bg.ac.rs/handle/123456789/3177
Collections
  • Publikacije
Institution/Community
Inovacioni centar
TY  - JOUR
AU  - Jevtić, Sonja
AU  - Stefanović, Anđela
AU  - Stanković, Dalibor
AU  - Pergal, Marija V.
AU  - Ivanović, Aleksandra T.
AU  - Jokić, Anja
AU  - Petković, Branka B.
PY  - 2018
UR  - https://cherry.chem.bg.ac.rs/handle/123456789/3177
AB  - Bentazone (BZ) is selective contact-past herbicide with suspected reproductive toxicity potential for human due to possible contamination of ground and surface waters. This work presents simple, rapid, sensitive and accurate determination of bentazone at unmodified boron-doped diamond electrode, using differential pulse voltammetry in Britton-Robinson buffer (pH 4, oxidation peak at 1.0 V). Under optimized DPV conditions linear calibration curve was obtained for range of 2 to 100 mu M, with a detection limit of 0.5 mu M. The effect of possible interfering agents is negligible, confirming good selectivity of the method. The method was successfully applied to determination of bentazone in spiked river water samples. This electrochemical determination of bentazone represents a favorable alternative to other used time-consuming and expensive analytical techniques and procedures.
PB  - Elsevier Science Sa, Lausanne
T2  - Diamond and Related Materials
T1  - Boron-doped diamond electrode - A prestigious unmodified carbon electrode for simple and fast determination of bentazone in river water samples
VL  - 81
SP  - 133
EP  - 137
DO  - 10.1016/j.diamond.2017.12.009
ER  - 
@article{
author = "Jevtić, Sonja and Stefanović, Anđela and Stanković, Dalibor and Pergal, Marija V. and Ivanović, Aleksandra T. and Jokić, Anja and Petković, Branka B.",
year = "2018",
abstract = "Bentazone (BZ) is selective contact-past herbicide with suspected reproductive toxicity potential for human due to possible contamination of ground and surface waters. This work presents simple, rapid, sensitive and accurate determination of bentazone at unmodified boron-doped diamond electrode, using differential pulse voltammetry in Britton-Robinson buffer (pH 4, oxidation peak at 1.0 V). Under optimized DPV conditions linear calibration curve was obtained for range of 2 to 100 mu M, with a detection limit of 0.5 mu M. The effect of possible interfering agents is negligible, confirming good selectivity of the method. The method was successfully applied to determination of bentazone in spiked river water samples. This electrochemical determination of bentazone represents a favorable alternative to other used time-consuming and expensive analytical techniques and procedures.",
publisher = "Elsevier Science Sa, Lausanne",
journal = "Diamond and Related Materials",
title = "Boron-doped diamond electrode - A prestigious unmodified carbon electrode for simple and fast determination of bentazone in river water samples",
volume = "81",
pages = "133-137",
doi = "10.1016/j.diamond.2017.12.009"
}
Jevtić, S., Stefanović, A., Stanković, D., Pergal, M. V., Ivanović, A. T., Jokić, A.,& Petković, B. B.. (2018). Boron-doped diamond electrode - A prestigious unmodified carbon electrode for simple and fast determination of bentazone in river water samples. in Diamond and Related Materials
Elsevier Science Sa, Lausanne., 81, 133-137.
https://doi.org/10.1016/j.diamond.2017.12.009
Jevtić S, Stefanović A, Stanković D, Pergal MV, Ivanović AT, Jokić A, Petković BB. Boron-doped diamond electrode - A prestigious unmodified carbon electrode for simple and fast determination of bentazone in river water samples. in Diamond and Related Materials. 2018;81:133-137.
doi:10.1016/j.diamond.2017.12.009 .
Jevtić, Sonja, Stefanović, Anđela, Stanković, Dalibor, Pergal, Marija V., Ivanović, Aleksandra T., Jokić, Anja, Petković, Branka B., "Boron-doped diamond electrode - A prestigious unmodified carbon electrode for simple and fast determination of bentazone in river water samples" in Diamond and Related Materials, 81 (2018):133-137,
https://doi.org/10.1016/j.diamond.2017.12.009 . .

DSpace software copyright © 2002-2015  DuraSpace
About CHERRY - CHEmistry RepositoRY | Send Feedback

re3dataOpenAIRERCUB
 

 

All of DSpaceInstitutions/communitiesAuthorsTitlesSubjectsThis institutionAuthorsTitlesSubjects

Statistics

View Usage Statistics

DSpace software copyright © 2002-2015  DuraSpace
About CHERRY - CHEmistry RepositoRY | Send Feedback

re3dataOpenAIRERCUB