Faculty of Chemistry Repository - Cherry
University of Belgrade - Faculty of Chemistry
    • English
    • Српски
    • Српски (Serbia)
  • English 
    • English
    • Serbian (Cyrillic)
    • Serbian (Latin)
  • Login
View Item 
  •   Cherry
  • Hemijski fakultet
  • Publikacije
  • View Item
  •   Cherry
  • Hemijski fakultet
  • Publikacije
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Comparison of non-destructive techniques and conventionally used spectrometric techniques for determination of elements in plant samples (coniferous leaves)

Thumbnail
2022
Comparison_of_non_pub_2022.pdf (2.959Mb)
Authors
Orlić, Jovana
Aničić-Urošević, Mira
Vergel, Konstantin
Zinicovscaia, Inga
Stojadinović, Sanja M.
Gržetić, Ivan
Ilijević, Konstantin
Article (Published version)
Metadata
Show full item record
Abstract
Conventionally used spectrometric techniques of inductively coupled plasma optical emission spectrometry (ICP-OES) and inductively coupled plasma optical emission spectrometry (ICP-MS) usually involve time-consuming sample preparation procedure of a sample dissolution which requires the usage of aggressive and toxic chemicals. The need for suitable and sustainable analytical methods for direct multi-elemental analysis of plant samples has been increased in recent years. Spectrometric techniques for direct sample analysis, instrumental neutron activation analysis (INAA) and X-ray fluorescence (XRF) have been applied in environmental studies and various fields of screening tests. Nevertheless, these techniques are not commonly used for plant sample analysis and their performances need to be evaluated. This research aimed to assess how reliable non-destructive techniques are in the determination of elements in plants compared to conventionally used spectrometric techniques. A total of 49 ...plant samples of four conifer species (Pinus nigra, Abies alba, Taxus baccata and Larix decidua) were measured using two conventionally applied (ICP-MS, ICP-OES) and two non-destructive techniques (wavelength dispersive XRF (WD-XRF), INAA). The comparison was performed by investigation of relative ratios of concentrations and by correlation analysis. Moreover, precision of the techniques was examined and compared. The quality control included analysis of NIST pine needles certified reference material (1575a) using all examined techniques. Our results suggest that additional analytical and quality control steps are necessary for reaching the highest accuracy of multi-elemental analysis.

Keywords:
multi-element determination / WD-XRF / standardless analysis / INAA / ICP-OES / ICP-MS
Source:
Journal of the Serbian Chemical Society, 2022, 87, 1, 69-81
Funding / projects:
  • Ministry of Education, Science and Technological Development, Republic of Serbia, Grant no. 200168 (University of Belgrade, Faculty of Chemistry) (RS-200168)
  • Ministry of Education, Science and Technological Development, Republic of Serbia, Grant no. 200026 (University of Belgrade, Institute of Chemistry, Technology and Metallurgy - IChTM) (RS-200026)

DOI: 10.2298/JSC210921101O

ISSN: 0352-5139

WoS: 000768809100007

Scopus: 2-s2.0-85124474681
[ Google Scholar ]
URI
http://cherry.chem.bg.ac.rs/handle/123456789/5007
Collections
  • Publikacije
Institution/Community
Hemijski fakultet
TY  - JOUR
AU  - Orlić, Jovana
AU  - Aničić-Urošević, Mira
AU  - Vergel, Konstantin
AU  - Zinicovscaia, Inga
AU  - Stojadinović, Sanja M.
AU  - Gržetić, Ivan
AU  - Ilijević, Konstantin
PY  - 2022
UR  - http://cherry.chem.bg.ac.rs/handle/123456789/5007
AB  - Conventionally used spectrometric techniques of inductively coupled plasma optical emission spectrometry (ICP-OES) and inductively coupled plasma optical emission spectrometry (ICP-MS) usually involve time-consuming sample preparation procedure of a sample dissolution which requires the usage of aggressive and toxic chemicals. The need for suitable and sustainable analytical methods for direct multi-elemental analysis of plant samples has been increased in recent years. Spectrometric techniques for direct sample analysis, instrumental neutron activation analysis (INAA) and X-ray fluorescence (XRF) have been applied in environmental studies and various fields of screening tests. Nevertheless, these techniques are not commonly used for plant sample analysis and their performances need to be evaluated. This research aimed to assess how reliable non-destructive techniques are in the determination of elements in plants compared to conventionally used spectrometric techniques. A total of 49 plant samples of four conifer species (Pinus nigra, Abies alba, Taxus baccata and Larix decidua) were measured using two conventionally applied (ICP-MS, ICP-OES) and two non-destructive techniques (wavelength dispersive XRF (WD-XRF), INAA). The comparison was performed by investigation of relative ratios of concentrations and by correlation analysis. Moreover, precision of the techniques was examined and compared. The quality control included analysis of NIST pine needles certified reference material (1575a) using all examined techniques. Our results suggest that additional analytical and quality control steps are necessary for reaching the highest accuracy of multi-elemental analysis.
T2  - Journal of the Serbian Chemical Society
T1  - Comparison of non-destructive techniques and conventionally used spectrometric techniques for determination of elements in plant samples (coniferous leaves)
VL  - 87
IS  - 1
SP  - 69
EP  - 81
DO  - 10.2298/JSC210921101O
ER  - 
@article{
author = "Orlić, Jovana and Aničić-Urošević, Mira and Vergel, Konstantin and Zinicovscaia, Inga and Stojadinović, Sanja M. and Gržetić, Ivan and Ilijević, Konstantin",
year = "2022",
abstract = "Conventionally used spectrometric techniques of inductively coupled plasma optical emission spectrometry (ICP-OES) and inductively coupled plasma optical emission spectrometry (ICP-MS) usually involve time-consuming sample preparation procedure of a sample dissolution which requires the usage of aggressive and toxic chemicals. The need for suitable and sustainable analytical methods for direct multi-elemental analysis of plant samples has been increased in recent years. Spectrometric techniques for direct sample analysis, instrumental neutron activation analysis (INAA) and X-ray fluorescence (XRF) have been applied in environmental studies and various fields of screening tests. Nevertheless, these techniques are not commonly used for plant sample analysis and their performances need to be evaluated. This research aimed to assess how reliable non-destructive techniques are in the determination of elements in plants compared to conventionally used spectrometric techniques. A total of 49 plant samples of four conifer species (Pinus nigra, Abies alba, Taxus baccata and Larix decidua) were measured using two conventionally applied (ICP-MS, ICP-OES) and two non-destructive techniques (wavelength dispersive XRF (WD-XRF), INAA). The comparison was performed by investigation of relative ratios of concentrations and by correlation analysis. Moreover, precision of the techniques was examined and compared. The quality control included analysis of NIST pine needles certified reference material (1575a) using all examined techniques. Our results suggest that additional analytical and quality control steps are necessary for reaching the highest accuracy of multi-elemental analysis.",
journal = "Journal of the Serbian Chemical Society",
title = "Comparison of non-destructive techniques and conventionally used spectrometric techniques for determination of elements in plant samples (coniferous leaves)",
volume = "87",
number = "1",
pages = "69-81",
doi = "10.2298/JSC210921101O"
}
Orlić, J., Aničić-Urošević, M., Vergel, K., Zinicovscaia, I., Stojadinović, S. M., Gržetić, I.,& Ilijević, K.. (2022). Comparison of non-destructive techniques and conventionally used spectrometric techniques for determination of elements in plant samples (coniferous leaves). in Journal of the Serbian Chemical Society, 87(1), 69-81.
https://doi.org/10.2298/JSC210921101O
Orlić J, Aničić-Urošević M, Vergel K, Zinicovscaia I, Stojadinović SM, Gržetić I, Ilijević K. Comparison of non-destructive techniques and conventionally used spectrometric techniques for determination of elements in plant samples (coniferous leaves). in Journal of the Serbian Chemical Society. 2022;87(1):69-81.
doi:10.2298/JSC210921101O .
Orlić, Jovana, Aničić-Urošević, Mira, Vergel, Konstantin, Zinicovscaia, Inga, Stojadinović, Sanja M., Gržetić, Ivan, Ilijević, Konstantin, "Comparison of non-destructive techniques and conventionally used spectrometric techniques for determination of elements in plant samples (coniferous leaves)" in Journal of the Serbian Chemical Society, 87, no. 1 (2022):69-81,
https://doi.org/10.2298/JSC210921101O . .

DSpace software copyright © 2002-2015  DuraSpace
About CHERRY - CHEmistry RepositoRY | Send Feedback

re3dataOpenAIRERCUB
 

 

All of DSpaceInstitutions/communitiesAuthorsTitlesSubjectsThis institutionAuthorsTitlesSubjects

Statistics

View Usage Statistics

DSpace software copyright © 2002-2015  DuraSpace
About CHERRY - CHEmistry RepositoRY | Send Feedback

re3dataOpenAIRERCUB