La(OH)3 Multi-Walled Carbon Nanotube/Carbon Paste-Based Sensing Approach for the Detection of Uric Acid—A Product of Environmentally Stressed Cells
Authors
Knežević, SaraOgnjanović, Miloš
Stanković, Vesna
Zlatanova, Milena
Nešić, Andrijana N.
Gavrović-Jankulović, Marija
Stanković, Dalibor
Article (Published version)
Metadata
Show full item recordAbstract
This paper aims to develop an amperometric, non-enzymatic sensor for detecting and quantifying UA as an alert signal induced by allergens with protease activity in human cell lines (HEK293 and HeLa). Uric acid (UA) has been classified as a damage-associated molecular pattern (DAMP) molecule that serves a physiological purpose inside the cell, while outside the cell it can be an indicator of cell damage. Cell damage or stress can be caused by different health problems or by environmental irritants, such as allergens. We can act and prevent the events that generate stress by determining the extent to which cells are under stress. Amperometric calibration measurements were performed with a carbon paste electrode modified with La(OH)3@MWCNT, at the potential of 0.3 V. The calibration curve was constructed in a linear operating range from 0.67 μM to 121 μM UA. The proposed sensor displayed good reproducibility with an RSD of 3.65% calculated for five subsequent measurements, and a low detec...tion limit of 64.28 nM, determined using the 3 S/m method. Interference studies and the real sample analysis of allergen-treated cell lines proved that the proposed sensing platform possesses excellent sensitivity, reproducibility, and stability. Therefore, it can potentially be used to evaluate stress factors in medical research and clinical practice.
Keywords:
La(OH)3@MWCNT / electrochemical sensor / uric acid / DAMP molecule / cell damage / stressSource:
Biosensors, 2022, 12, 9, 705-Publisher:
- MDPI
Funding / projects:
- Ministry of Science, Technological Development and Innovation of the Republic of Serbia, institutional funding - 200168 (University of Belgrade, Faculty of Chemistry) (RS-MESTD-inst-2020-200168)
- Ministry of Science and Higher Education of the Russian Federation (agreement No. 075-15-2022-1135)
Note:
- Supplementary material: https://cherry.chem.bg.ac.rs/handle/123456789/5632
Related info:
Collections
Institution/Community
Hemijski fakultet / Faculty of ChemistryTY - JOUR AU - Knežević, Sara AU - Ognjanović, Miloš AU - Stanković, Vesna AU - Zlatanova, Milena AU - Nešić, Andrijana N. AU - Gavrović-Jankulović, Marija AU - Stanković, Dalibor PY - 2022 UR - http://cherry.chem.bg.ac.rs/handle/123456789/5622 AB - This paper aims to develop an amperometric, non-enzymatic sensor for detecting and quantifying UA as an alert signal induced by allergens with protease activity in human cell lines (HEK293 and HeLa). Uric acid (UA) has been classified as a damage-associated molecular pattern (DAMP) molecule that serves a physiological purpose inside the cell, while outside the cell it can be an indicator of cell damage. Cell damage or stress can be caused by different health problems or by environmental irritants, such as allergens. We can act and prevent the events that generate stress by determining the extent to which cells are under stress. Amperometric calibration measurements were performed with a carbon paste electrode modified with La(OH)3@MWCNT, at the potential of 0.3 V. The calibration curve was constructed in a linear operating range from 0.67 μM to 121 μM UA. The proposed sensor displayed good reproducibility with an RSD of 3.65% calculated for five subsequent measurements, and a low detection limit of 64.28 nM, determined using the 3 S/m method. Interference studies and the real sample analysis of allergen-treated cell lines proved that the proposed sensing platform possesses excellent sensitivity, reproducibility, and stability. Therefore, it can potentially be used to evaluate stress factors in medical research and clinical practice. PB - MDPI T2 - Biosensors T1 - La(OH)3 Multi-Walled Carbon Nanotube/Carbon Paste-Based Sensing Approach for the Detection of Uric Acid—A Product of Environmentally Stressed Cells VL - 12 IS - 9 SP - 705 DO - 10.3390/bios12090705 ER -
@article{ author = "Knežević, Sara and Ognjanović, Miloš and Stanković, Vesna and Zlatanova, Milena and Nešić, Andrijana N. and Gavrović-Jankulović, Marija and Stanković, Dalibor", year = "2022", abstract = "This paper aims to develop an amperometric, non-enzymatic sensor for detecting and quantifying UA as an alert signal induced by allergens with protease activity in human cell lines (HEK293 and HeLa). Uric acid (UA) has been classified as a damage-associated molecular pattern (DAMP) molecule that serves a physiological purpose inside the cell, while outside the cell it can be an indicator of cell damage. Cell damage or stress can be caused by different health problems or by environmental irritants, such as allergens. We can act and prevent the events that generate stress by determining the extent to which cells are under stress. Amperometric calibration measurements were performed with a carbon paste electrode modified with La(OH)3@MWCNT, at the potential of 0.3 V. The calibration curve was constructed in a linear operating range from 0.67 μM to 121 μM UA. The proposed sensor displayed good reproducibility with an RSD of 3.65% calculated for five subsequent measurements, and a low detection limit of 64.28 nM, determined using the 3 S/m method. Interference studies and the real sample analysis of allergen-treated cell lines proved that the proposed sensing platform possesses excellent sensitivity, reproducibility, and stability. Therefore, it can potentially be used to evaluate stress factors in medical research and clinical practice.", publisher = "MDPI", journal = "Biosensors", title = "La(OH)3 Multi-Walled Carbon Nanotube/Carbon Paste-Based Sensing Approach for the Detection of Uric Acid—A Product of Environmentally Stressed Cells", volume = "12", number = "9", pages = "705", doi = "10.3390/bios12090705" }
Knežević, S., Ognjanović, M., Stanković, V., Zlatanova, M., Nešić, A. N., Gavrović-Jankulović, M.,& Stanković, D.. (2022). La(OH)3 Multi-Walled Carbon Nanotube/Carbon Paste-Based Sensing Approach for the Detection of Uric Acid—A Product of Environmentally Stressed Cells. in Biosensors MDPI., 12(9), 705. https://doi.org/10.3390/bios12090705
Knežević S, Ognjanović M, Stanković V, Zlatanova M, Nešić AN, Gavrović-Jankulović M, Stanković D. La(OH)3 Multi-Walled Carbon Nanotube/Carbon Paste-Based Sensing Approach for the Detection of Uric Acid—A Product of Environmentally Stressed Cells. in Biosensors. 2022;12(9):705. doi:10.3390/bios12090705 .
Knežević, Sara, Ognjanović, Miloš, Stanković, Vesna, Zlatanova, Milena, Nešić, Andrijana N., Gavrović-Jankulović, Marija, Stanković, Dalibor, "La(OH)3 Multi-Walled Carbon Nanotube/Carbon Paste-Based Sensing Approach for the Detection of Uric Acid—A Product of Environmentally Stressed Cells" in Biosensors, 12, no. 9 (2022):705, https://doi.org/10.3390/bios12090705 . .