Application of Screen Printed Diamond Electrode, Coupled with “Point-of-Care” Platform, for Nanomolar Quantification of Phytonutrient Pterostilbene in Dietary Supplements: An Experimental Study Supported by Theory
Authors
Đurđić, Slađana
Vlahović, Filip

Markićević, Milan
Mutić, Jelena

Manojlović, Dragan D.

Stanković, Vesna
Švorc, Ľubomír
Stanković, Dalibor

Article (Published version)
Metadata
Show full item recordAbstract
Herein, a screen–printed diamond electrode (SPDE) coupled with a “point-of-care” platform (30 µL-drop concepts, single-drop-detection approach) was successfully applied for the electrochemical determination of pterostilbene (PTS). Cyclic voltammetry identified irreversible oxidation of PTS, where oxidation peak was shown to be strongly dependent on the pH of the working environmental. Although the proposition of the detailed electrochemical oxidation mechanism of PTS goes out of the scope of the present research, we have determined the most probable reactive site of our analyte, by utilizing DFT-based reactivity descriptors (Fukui functions). For electrochemical quantification of PTS, oxidation peak at 0.32 V (vs. Ag/AgCl) was followed in presence of 0.5 mol L−1 of Briton–Robinson buffer solution (pH = 9). Coupled with the optimized parameters of differential pulse voltammetry (DPV), SPDE detected PTS in two linear ranges (first range was from 0.011 to 0.912 µmol L−1; second range was ...from 0.912 to 4.420 µmol L−1), providing the LOD and LOQ on a nanomolar level (3.1 nmol L−1 and 10.0 nmol L−1, respectively). The selectivity of the optimized DPV method was found to be excellent, with the current changes of less than 7%, in the presence of ten times higher concentrations of the certain interferences. The practical applicability of the SPDE and single-drop-detection approach in dietary supplements (with a declared PTS content of 50 mg/tablet), with the recovery values ranging from 95 to 102%, shows that the developed method has high potential for precise and accurate PTS detection, as well as exceptional miniaturization possibilities of relevant equipment for on-site sensing.
Keywords:
“point-of-care” platform / B3LYP / density functional theory / DFT / dietary supplements / electrochemical determination / Fukui functions / pterostilbene / screen-printed diamond electrode / single-drop-detection approachSource:
Chemosensors, 2023, 11, 1, 15-Publisher:
- MDPI
Funding / projects:
- Ministry of Education, Science and Technological Development, Republic of Serbia, Grant no. 200168 (University of Belgrade, Faculty of Chemistry) (RS-200168)
- Ministry of Education, Science and Technological Development, Republic of Serbia, Grant no. 200026 (University of Belgrade, Institute of Chemistry, Technology and Metallurgy - IChTM) (RS-200026)
Note:
- Supplementary material: https://cherry.chem.bg.ac.rs/handle/123456789/5839
Related info:
- Referenced by
https://cherry.chem.bg.ac.rs/handle/123456789/5839
Collections
Institution/Community
Hemijski fakultet / Faculty of ChemistryTY - JOUR AU - Đurđić, Slađana AU - Vlahović, Filip AU - Markićević, Milan AU - Mutić, Jelena AU - Manojlović, Dragan D. AU - Stanković, Vesna AU - Švorc, Ľubomír AU - Stanković, Dalibor PY - 2023 UR - http://cherry.chem.bg.ac.rs/handle/123456789/5812 AB - Herein, a screen–printed diamond electrode (SPDE) coupled with a “point-of-care” platform (30 µL-drop concepts, single-drop-detection approach) was successfully applied for the electrochemical determination of pterostilbene (PTS). Cyclic voltammetry identified irreversible oxidation of PTS, where oxidation peak was shown to be strongly dependent on the pH of the working environmental. Although the proposition of the detailed electrochemical oxidation mechanism of PTS goes out of the scope of the present research, we have determined the most probable reactive site of our analyte, by utilizing DFT-based reactivity descriptors (Fukui functions). For electrochemical quantification of PTS, oxidation peak at 0.32 V (vs. Ag/AgCl) was followed in presence of 0.5 mol L−1 of Briton–Robinson buffer solution (pH = 9). Coupled with the optimized parameters of differential pulse voltammetry (DPV), SPDE detected PTS in two linear ranges (first range was from 0.011 to 0.912 µmol L−1; second range was from 0.912 to 4.420 µmol L−1), providing the LOD and LOQ on a nanomolar level (3.1 nmol L−1 and 10.0 nmol L−1, respectively). The selectivity of the optimized DPV method was found to be excellent, with the current changes of less than 7%, in the presence of ten times higher concentrations of the certain interferences. The practical applicability of the SPDE and single-drop-detection approach in dietary supplements (with a declared PTS content of 50 mg/tablet), with the recovery values ranging from 95 to 102%, shows that the developed method has high potential for precise and accurate PTS detection, as well as exceptional miniaturization possibilities of relevant equipment for on-site sensing. PB - MDPI T2 - Chemosensors T1 - Application of Screen Printed Diamond Electrode, Coupled with “Point-of-Care” Platform, for Nanomolar Quantification of Phytonutrient Pterostilbene in Dietary Supplements: An Experimental Study Supported by Theory VL - 11 IS - 1 SP - 15 DO - 10.3390/chemosensors11010015 ER -
@article{ author = "Đurđić, Slađana and Vlahović, Filip and Markićević, Milan and Mutić, Jelena and Manojlović, Dragan D. and Stanković, Vesna and Švorc, Ľubomír and Stanković, Dalibor", year = "2023", abstract = "Herein, a screen–printed diamond electrode (SPDE) coupled with a “point-of-care” platform (30 µL-drop concepts, single-drop-detection approach) was successfully applied for the electrochemical determination of pterostilbene (PTS). Cyclic voltammetry identified irreversible oxidation of PTS, where oxidation peak was shown to be strongly dependent on the pH of the working environmental. Although the proposition of the detailed electrochemical oxidation mechanism of PTS goes out of the scope of the present research, we have determined the most probable reactive site of our analyte, by utilizing DFT-based reactivity descriptors (Fukui functions). For electrochemical quantification of PTS, oxidation peak at 0.32 V (vs. Ag/AgCl) was followed in presence of 0.5 mol L−1 of Briton–Robinson buffer solution (pH = 9). Coupled with the optimized parameters of differential pulse voltammetry (DPV), SPDE detected PTS in two linear ranges (first range was from 0.011 to 0.912 µmol L−1; second range was from 0.912 to 4.420 µmol L−1), providing the LOD and LOQ on a nanomolar level (3.1 nmol L−1 and 10.0 nmol L−1, respectively). The selectivity of the optimized DPV method was found to be excellent, with the current changes of less than 7%, in the presence of ten times higher concentrations of the certain interferences. The practical applicability of the SPDE and single-drop-detection approach in dietary supplements (with a declared PTS content of 50 mg/tablet), with the recovery values ranging from 95 to 102%, shows that the developed method has high potential for precise and accurate PTS detection, as well as exceptional miniaturization possibilities of relevant equipment for on-site sensing.", publisher = "MDPI", journal = "Chemosensors", title = "Application of Screen Printed Diamond Electrode, Coupled with “Point-of-Care” Platform, for Nanomolar Quantification of Phytonutrient Pterostilbene in Dietary Supplements: An Experimental Study Supported by Theory", volume = "11", number = "1", pages = "15", doi = "10.3390/chemosensors11010015" }
Đurđić, S., Vlahović, F., Markićević, M., Mutić, J., Manojlović, D. D., Stanković, V., Švorc, Ľ.,& Stanković, D.. (2023). Application of Screen Printed Diamond Electrode, Coupled with “Point-of-Care” Platform, for Nanomolar Quantification of Phytonutrient Pterostilbene in Dietary Supplements: An Experimental Study Supported by Theory. in Chemosensors MDPI., 11(1), 15. https://doi.org/10.3390/chemosensors11010015
Đurđić S, Vlahović F, Markićević M, Mutić J, Manojlović DD, Stanković V, Švorc Ľ, Stanković D. Application of Screen Printed Diamond Electrode, Coupled with “Point-of-Care” Platform, for Nanomolar Quantification of Phytonutrient Pterostilbene in Dietary Supplements: An Experimental Study Supported by Theory. in Chemosensors. 2023;11(1):15. doi:10.3390/chemosensors11010015 .
Đurđić, Slađana, Vlahović, Filip, Markićević, Milan, Mutić, Jelena, Manojlović, Dragan D., Stanković, Vesna, Švorc, Ľubomír, Stanković, Dalibor, "Application of Screen Printed Diamond Electrode, Coupled with “Point-of-Care” Platform, for Nanomolar Quantification of Phytonutrient Pterostilbene in Dietary Supplements: An Experimental Study Supported by Theory" in Chemosensors, 11, no. 1 (2023):15, https://doi.org/10.3390/chemosensors11010015 . .