Приказ основних података о документу

dc.creatorPastor, Ferenc
dc.creatorDejmkova, Hana
dc.creatorZima, Jiri
dc.creatorBarek, Jiri
dc.date.accessioned2018-11-22T00:19:29Z
dc.date.available2018-11-22T00:19:29Z
dc.date.issued2011
dc.identifier.issn0010-0765
dc.identifier.urihttps://cherry.chem.bg.ac.rs/handle/123456789/1334
dc.description.abstractThe possibility of determination of chloramphenicol by differential pulse voltammetry at four different carbon paste electrodes, in the full pH range (2-12) of Britton-Robinson (BR) buffer was investigated. Electrodes were prepared by mixing spectroscopic graphite powder or glassy carbon microbeads with mineral oil (Nujol) or tricresyl phosphate. Under optimal conditions (BR buffer pH 12, the electrode prepared from glassy carbon microbeads and tricresyl phosphate), linear calibration graph was obtained only in 10-5 M chloramphenicol concentration range. Determination of lower concentrations of chloramphenicol was complicated by irreproducible peak of oxygen from the carbon paste which overlapped with peak of chloramphenicol. Addition of sodium sulfite removed the oxygen peak without influence on the peak of chloramphenicol. Under optimal conditions (electrode paste made from glassy carbon microbeads, BR buffer pH 10 and 0.5 M sodium sulfite), straight calibration line was obtained in the 10(-6) and 10(-5) M chloramphenicol concentration range. Limit of determination was 5 x 10(-7) mol/l.en
dc.publisherInst Organic Chem And Biochem, Prague 6
dc.relationinfo:eu-repo/grantAgreement/MESTD/Integrated and Interdisciplinary Research (IIR or III)/43010/RS//
dc.relation[SVV 2010-10-261204]
dc.relationMinistry of Education, Youth and Sports of the Czech Republic [LC 06035, MSM 0021620857, ME 10004]
dc.rightsrestrictedAccess
dc.sourceCollection of Czechoslovak Chemical Communications
dc.subjectChloramphenicolen
dc.subjectCarbon paste electrodesen
dc.subjectOxygen peaken
dc.subjectOxygen removalen
dc.subjectSodium sulfiteen
dc.subjectDifferential pulse voltammetryen
dc.titleDetermination of Chloramphenicol by Differential Pulse Voltammetry at Carbon Paste Electrodes - the Use of Sodium Sulfite for Removal of Oxygen from Electrode Surfaceen
dc.typearticle
dc.rights.licenseARR
dcterms.abstractПастор, Ференц; Зима, Јири; Барек, Јири; Дејмкова, Хана;
dc.citation.volume76
dc.citation.issue5
dc.citation.spage383
dc.citation.epage397
dc.identifier.wos000290280100003
dc.identifier.doi10.1135/cccc2011011
dc.citation.other76(5): 383-397
dc.citation.rankM23
dc.type.versionpublishedVersion
dc.identifier.scopus2-s2.0-79955668919


Документи

Thumbnail

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу