Приказ основних података о документу
Optimization and application of the gas-diffusion flow injection method for the determination of chloride
Optimizacija i primena gasno-difuzione protočne injekcione metode za određivanje hlorida
dc.creator | Lolić, Aleksandar | |
dc.creator | Nikolić-Mandić, Snežana D. | |
dc.creator | Polić, Predrag S. | |
dc.date.accessioned | 2018-11-22T00:04:06Z | |
dc.date.available | 2018-11-22T00:04:06Z | |
dc.date.issued | 2001 | |
dc.identifier.issn | 0352-5139 | |
dc.identifier.uri | https://cherry.chem.bg.ac.rs/handle/123456789/473 | |
dc.description.abstract | A selective and sensitive procedure for the fast and indirect determination of chloride by the gas-diffusion FIA method has been optimized and applied for the determination of chloride in water samples which contained different amounts of the analyte. The examined samples were: seawater, tap water and very pure water from the water-steam system of the power plant "Nikola Tesla B" in Obrenovac. Application of an amperometric detector (model LC-17A; BAS, West Lafayette, USA) enables the detection limit to be decreased down to 0.05 mu mol/dm(3) of chloride, which col responds to 35.5 pg, and adjustment of the acceptor flow rate and direction inside the gas-diffusion unit. In this way the optimized FIA system has excellent repeatability. For 5 mu mol/dm(3) it was found to be 1.11% (n = 5). The throughput of this method is 60 samples per hour. | en |
dc.description.abstract | Selektivan i osetljiv postupak za brzo, indirektno određivanje hlorida gasno-difuzionom metodom otpimizovan je i primenjen za određivanje hlorida u uzorcima voda sa vrlo različitim sadržajem ove vrste: morskoj, vodi za piće i vrlo čistim vodama u sistemu voda-para TE "Nikola Tesna B" u Obrenovcu. Upotreba amperometrijskog detektora tipa LC-17A omogućava snižavanje granice detekcije na 0.05 μmol/dm3 hlorida (što za uzorak zapremine 0.2 cm3 iznosi 35.5 pg) i podešavanje brzine i smera toka u gasno-difuzionoj jedinici. Ovako optimizovan protočni sistem ima odličnu reproduktivnost. Za hloridni standard koncentracije 5 μmol/dm3 relativna standardna devijacija iznosi 1.11 % (n = 5). | sr |
dc.publisher | Serbian Chemical Soc, Belgrade | |
dc.rights | openAccess | |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.source | Journal of the Serbian Chemical Society | |
dc.subject | gas-diffusion flow injection method | en |
dc.subject | amperometric detection | en |
dc.subject | amperometric detection | en |
dc.subject | indirect chloride determination | en |
dc.subject | indirect chloride determination | en |
dc.title | Optimization and application of the gas-diffusion flow injection method for the determination of chloride | en |
dc.title | Optimizacija i primena gasno-difuzione protočne injekcione metode za određivanje hlorida | sr |
dc.type | article | |
dc.rights.license | BY-NC-ND | |
dcterms.abstract | Полиц, П; Николиц-Мандиц, С; Лолић, Aлександар; Оптимизација и примена гасно-дифузионе проточне ињекционе методе за одређивање хлорида; Оптимизација и примена гасно-дифузионе проточне ињекционе методе за одређивање хлорида; | |
dc.citation.volume | 66 | |
dc.citation.issue | 9 | |
dc.citation.spage | 637 | |
dc.citation.epage | 646 | |
dc.identifier.wos | 000171531500008 | |
dc.citation.other | 66(9): 637-646 | |
dc.citation.rank | M23 | |
dc.type.version | publishedVersion | |
dc.identifier.fulltext | https://cherry.chem.bg.ac.rs/bitstream/id/9777/471.pdf | |
dc.identifier.rcub | https://hdl.handle.net/21.15107/rcub_cherry_473 |