Приказ основних података о документу

Optimizacija i primena gasno-difuzione protočne injekcione metode za određivanje hlorida

dc.creatorLolić, Aleksandar
dc.creatorNikolić-Mandić, Snežana D.
dc.creatorPolić, Predrag S.
dc.date.accessioned2018-11-22T00:04:06Z
dc.date.available2018-11-22T00:04:06Z
dc.date.issued2001
dc.identifier.issn0352-5139
dc.identifier.urihttps://cherry.chem.bg.ac.rs/handle/123456789/473
dc.description.abstractA selective and sensitive procedure for the fast and indirect determination of chloride by the gas-diffusion FIA method has been optimized and applied for the determination of chloride in water samples which contained different amounts of the analyte. The examined samples were: seawater, tap water and very pure water from the water-steam system of the power plant "Nikola Tesla B" in Obrenovac. Application of an amperometric detector (model LC-17A; BAS, West Lafayette, USA) enables the detection limit to be decreased down to 0.05 mu mol/dm(3) of chloride, which col responds to 35.5 pg, and adjustment of the acceptor flow rate and direction inside the gas-diffusion unit. In this way the optimized FIA system has excellent repeatability. For 5 mu mol/dm(3) it was found to be 1.11% (n = 5). The throughput of this method is 60 samples per hour.en
dc.description.abstractSelektivan i osetljiv postupak za brzo, indirektno određivanje hlorida gasno-difuzionom metodom otpimizovan je i primenjen za određivanje hlorida u uzorcima voda sa vrlo različitim sadržajem ove vrste: morskoj, vodi za piće i vrlo čistim vodama u sistemu voda-para TE "Nikola Tesna B" u Obrenovcu. Upotreba amperometrijskog detektora tipa LC-17A omogućava snižavanje granice detekcije na 0.05 μmol/dm3 hlorida (što za uzorak zapremine 0.2 cm3 iznosi 35.5 pg) i podešavanje brzine i smera toka u gasno-difuzionoj jedinici. Ovako optimizovan protočni sistem ima odličnu reproduktivnost. Za hloridni standard koncentracije 5 μmol/dm3 relativna standardna devijacija iznosi 1.11 % (n = 5).sr
dc.publisherSerbian Chemical Soc, Belgrade
dc.rightsopenAccess
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.sourceJournal of the Serbian Chemical Society
dc.subjectgas-diffusion flow injection methoden
dc.subjectamperometric detectionen
dc.subjectamperometric detectionen
dc.subjectindirect chloride determinationen
dc.subjectindirect chloride determinationen
dc.titleOptimization and application of the gas-diffusion flow injection method for the determination of chlorideen
dc.titleOptimizacija i primena gasno-difuzione protočne injekcione metode za određivanje hloridasr
dc.typearticle
dc.rights.licenseBY-NC-ND
dcterms.abstractПолиц, П; Николиц-Мандиц, С; Лолић, Aлександар; Оптимизација и примена гасно-дифузионе проточне ињекционе методе за одређивање хлорида; Оптимизација и примена гасно-дифузионе проточне ињекционе методе за одређивање хлорида;
dc.citation.volume66
dc.citation.issue9
dc.citation.spage637
dc.citation.epage646
dc.identifier.wos000171531500008
dc.citation.other66(9): 637-646
dc.citation.rankM23
dc.type.versionpublishedVersion
dc.identifier.fulltexthttps://cherry.chem.bg.ac.rs/bitstream/id/9777/471.pdf
dc.identifier.rcubhttps://hdl.handle.net/21.15107/rcub_cherry_473